Journal: :The Journal of experimental biology 2010
N A Curtin F Lou R C Woledge

The mechanical performance of red and white muscle fibres from dogfish was compared during a long series of contractions with sinusoidal movement or under isometric conditions at 12 degrees C (normal in vivo temperature). Power output was measured during sinusoidal movement at 0.75 Hz and peak-to-peak amplitude about 12% L(0). Tetanus duty cycle was 33% (0.44 s) at phase -8% (first stimulus at ...

Journal: :The American journal of physiology 1975
R J Paul J W Peterson

The length-tension and length-oxygen consumption rate relationships were studied in bovine mesenteric vein at 37 degrees C. The absence of spontaneous mechanical activity permits straightforward interpretation in terms of active (smooth muscle) and passive components of the vein wall. Longitudinal loops, the predominant smooth muscle component being oriented in the longitudinal (axial) directio...

Journal: :Biophysical journal 2000
K A Schmitz D L Holcomb-Wygle D J Oberski C B Lindemann

The force generated by a detergent-extracted reactivated bull sperm flagellum during an isometric stall was measured with a force-calibrated glass microprobe. The average isometric stall force from 48 individual measurements was 2.5 +/- 0.7 x 10(-5) dyne (2.5 +/- 0.7 x 10(-10) N). The force measurements were obtained by positioning a calibrated microprobe in the beat path of sperm cells that we...

Journal: :The Journal of General Physiology 1988
DM Warshaw DD Rees FS Fay

Force development in smooth muscle, as in skeletal muscle, is believed to reflect recruitment of force-generating myosin cross-bridges. However, little is known about the events underlying cross-bridge recruitment as the muscle cell approaches peak isometric force and then enters a period of tension maintenance. In the present studies on single smooth muscle cells isolated from the toad (Bufo m...

Journal: :Proceedings. Biological sciences 2008
Dilson E Rassier

When activated skeletal muscle is stretched, force increases in two phases. This study tested the hypothesis that the increase in stretch force during the first phase is produced by pre-power stroke cross bridges. Myofibrils were activated in sarcomere lengths (SLs) between 2.2 and 2.5 microm, and stretched by approximately 5-15 per cent SL. When stretch was performed at 1 microms-1SL-1, the tr...

2005
BY H. IWAMOTO A. MURAOKA A. GOTO

1. Fibres from adductor scutorum muscle of a barnacle Tetraclita squamosa were made to contract isometrically by electrical stimulation, and the change in the ability to shorten actively during the mechanical responses was examined by suddenly allowing the fibres to shorten under a very small load (<3 % of the force immediately before shortening) at various times after the onset of stimulation....

Journal: :Journal of rehabilitation research and development 2003
Robert J Goldman Kirk A Reinbold Z Annette Iglarsh Lawrence M Neustadter Carol A Oatis H Ralph Schumacher

Our long-term goal is to improve adherence to a home-based isometric program for rehabilitation of knee osteoarthritis (OA) using a force-biofeedback device (Isopad). Our goal for Phase I was to design and evaluate an Isopad-based program in a supervised clinical setting. Our subjects were five patients with knee OA of Kellgren stage II or greater. A capacitive force sensor was tested for accur...

1998
LAUREN E. SERGIO JOHN F. KALASKA

Sergio, Lauren E. and John F. Kalaska. Changes in the temporal correlated with other spatial kinematic parameters of handpattern of primary motor cortex activity in a directional isometric paths, including the direction and velocity of hand movement force versus limb movement task. J. Neurophysiol. 80: 1577– and target distance (Ashe and Georgopoulos 1994; Fu et al. 1583, 1998. We recorded the ...

Journal: :Journal of biomechanics 2007
Junichiro Yamauchi Chizuko Mishima Makoto Fujiwara Satoshi Nakayama Naokata Ishii

To study the force-velocity characteristics of human knee-hip extension movement, a dynamometer, in which force was controlled by a servo system, was developed. Seated subjects pressed either bilaterally or unilaterally a force plate, a horizontal position of which was servo-controlled so as to equalize the measured force and a force command generated by a computer at a time resolution of 2 ms ...

2015
Christopher Thomas Paul Comfort Chieh-Ying Chiang Paul A. Jones

Objectives: The aim of this investigation was to assess the use of isometric strength testing as a determinant of sprint and change of direction performance in collegiate athletes. Design and Methods: Fourteen male collegiate athletes (mean ± SD; age = 21 ± 2.4 years; height =176 ± 9.0 cm; body mass = 72.8 ± 9.4 kg) participated in the study. Maximal strength was assessed via an isometric mid-t...

نمودار تعداد نتایج جستجو در هر سال