نتایج جستجو برای: hexavalent chromium

تعداد نتایج: 23366  

Journal: :Ecotoxicology and environmental safety 2008
Jun Yao Lin Tian Yanxin Wang Atakora Djah Fei Wang Huilun Chen Chunli Su Rensheng Zhuang Yong Zhou Martin M F Choi Emilia Bramanti

A multi-channel thermal activity monitor was applied to study soil microbial activity in Wuhan brown sandy soil in the presence of different concentrations of hexavalent chromium (K(2)Cr(2)O(7)). In order to stimulate the soil microbial activity, 5.0mg of glucose and 5.0mg of ammonium sulfate were added to a 1.20-g soil sample under a controlled humidity of 35%. The results show that the poison...

Journal: :تحقیقات نظام سلامت 0

abstract background: heavy metals in industrial wastewater especially chromium (vi) are considered as the main environmental pollutants. methods: electrochemical cell made of plexiglass with a volume of 1.95 lit was used. iron and graphite electrodes, electricity conductor, each with dimensions of 0.1×3×10 cm (width×length×height) were designed and built. tests were carried out in various condi...

Journal: :environmental health engineering and management 0
ali asghar najafpoor health sciences research center, department of environmental health engineering, school of health, mashhad university of medical sciences, mashhad, iran ghorban soleimani shahid sadoughi university of medical sciences, yazd, iran mohammad hasan ehrampoush environmental health engineering department, shahid sadoughi university of medical sciences, yazd, iran mohammad taghi ghaneian environmental health engineering department, shahid sadoughi university of medical sciences, yazd, iran elham rahmanpour salmani department of environmental health, school of health, mashhad university of medical sciences, mashhad, iran maryam dolatabadi takabi student research committee, department of environmental health, school of health, mashhad university of medical sciences, mashhad, iran

background: the presence of heavy metals in the environment especially in water supplies have caused many concerns because of their toxicity and non-degradability. hexavalent chromium (cr) is one of the most toxic metals which is used in many industries, so it is essential to remove it from industrial wastewater. in this study, we made a comparison between different adsorption isotherms in the ...

Journal: :international archives of health sciences 0
m. haghighi environmental health engineering department, health faculty, kashan university of medical sciences, kashan, iran f. rahmani chemical engineering faculty, sahand university of technology, sahand new town, iran r. dehghani social determinants of health (sdh) research center and department of environment health, kashan university of medical sciences, kashan, ir iranhealth engineering department, health faculty, kashan university of medical sciences, kashan, iran a. mazaheri tehrani social determinants of health (sdh) research center and department of environment health, kashan university of medical sciences, kashan, ir iranhealth engineering department, health faculty, kashan university of medical sciences, kashan, iran m.b. miranzadeh post address: qotb-e-ravandi avenue, pezeshk boulevard, kashan university of medical sciences, kashan, iran

abstract aims: the application of photocatalytic processes to remove heavy metals in aqueous solutions and industrial wastewater are regarded as extremely effective, clean and without producing waste methods. the goal of the present study was to investigate the photocatalytic activity of zno based on h-zsm-5 zeolite support. materials & methods: zno/h-zsm-5 composite synthesized by impregnation...

2011
Herman Gibb Heather J. Hoffman Cary Haver

This analysis of an epidemiologic study of chromate production workers evaluates several variables related to the biologic understanding of chromate-induced lung cancer. Age at hire was found to be negatively associated with lung cancer risk. Reducing exposure was found to have benefits that extended into older age, and the benefits were greater when the reduction began at an earlier age. The s...

2007
CHULSUNG KIM YEQING LAN BAOLIN DENG

Hexavalent chromium reduction by sulfide in the presence of goethite was studied through several batch experiments. Under our specific experimental conditions including 20 μM of hexavalent chromium, 560–1117 μM of sulfide and 10.61– 37.13 m2/L of goethite at pH of 8.45 controlled by 0.1 M borate buffer, the obtained hexavalent chromium disappearance rate was –d[Cr(VI)]/dt = k[surface area of go...

2013
T. Raghuraman

Tannery effluent is a major source of aquatic pollution in India. Hexavalent chromium compounds are being used in a wide variety of commercial processes and unregulated disposal of the chromium containing effluent has led to the contamination of soil, sediment, surface and ground waters. In trace amounts, chromium is considered an essential nutrient for numerous organisms, but at higher level, ...

2017
Moshood Keke Mustapha

Hexavalent chromium is a bio accumulative toxic metal in water and fish. It enters aquaculture ponds mainly through anthropogenic sources. Hexavalent chromium concentrations and its effects on the morphology and behavior of Clarias gariepinus were investigated from four aquaculture ponds for 12 weeks. Chromium was measured using diphenyl carbohdrazide method; alkalinity and hardness were measur...

2013
K. A. Idriss

A rapid, reliable and accurate method for the determination of hexavalent chromium in Portland cement is developed. The proposed method includes direct spectrophotometric determination of Cr (VI) in Portland cement with 1, 2, 5, 8 Tetrahydroxyanthraquinone, (Quinalizarin, QINZ) at pH 1.5. The European Directive (2003/53/EC) limits the use of cements so that it contains no more than 2 mg·Kg of w...

2016

A mixed plating rinse wastewater containing zinc, hexavalent chromium, trivalent chromium, and cyanide with total dissolved solids of 424 mg/1 was treated by a model consisting of a sand filter and ion exchange columns. A strongly acidic cation resin in hydrogen form and a strongly basic anion resin in hydroxide form were used in the columns as cationic and anionic exchangers, respectively. The...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید