نتایج جستجو برای: glandular absorbed dose
تعداد نتایج: 332419 فیلتر نتایج به سال:
background: radioiodine therapy has proven to be an effective method in the treatment of patients with differentiated thyroid carcinoma after thyroidectomy. the scope of this study is to describe a method to obtain the dose of organs using medical internal radiation dosimetry (mird) method. at the end, the results of mird calculations were compared with thermoluminescent dosimeter (tld-100). ma...
background: the electron contamination may reduce or even diminish the skin sparing property of the megavoltage beam. the detailed characteristics of contaminant electrons are presented for different field sizes and cases. materials and methods: the monte carlo code, mcnpx, has been used to simulate 18 mv photon beam from a varian linac-2300 accelerator. all dose measurements were carried out u...
The routine assessment of patient dose in the National Health Service Breast Screening Programme is performed as part of the quality assurance protocol recommended by the Institute of Physical Sciences in Medicine. The mean glandular dose to a standard breast is deduced from measurement of the air kerma at the entrance surface of a 4 cm Perspex phantom by applying a series of conversion factors...
With the advent of new detector technology, digital tomosynthesis imaging of the breast has, in the past few years, become a technique intensely investigated as a replacement for planar mammography. As with all other x-ray-based imaging methods, radiation dose is of utmost concern in the development of this new imaging technology. For virtually all development and optimization studies, knowledg...
Background and Aims: The evaluation of absorbed dose received by patients could give useful information for radiation risk estimation. This study was performed to compare the entrance skin dose received by patients in cone beam computed tomography (CBCT), conventional and spiral computed tomography (CT).Materials and Methods: In this experimental study, 81 calibrated TLD chips were used. the TL...
Objective(s): To investigate and compare quantitative accuracy of kidney absorbed dose measures made from both 2D and 3D imaging in patients receiving 177LuDOTATATE (Lutate) for treatment of neuroendocrine tumours (NETs). Methods: Patients receiving Lutate therapy underwent both whole body planar imaging and SPECT/CT imaging over the kidneys at time points 0.5, 4, 24, and 96-120 hours after inj...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید