نتایج جستجو برای: gas insulated substations

تعداد نتایج: 249589  

2017
Ju Tang Xu Yang Dong Yang Qiang Yao Yulong Miao Chaohai Zhang Fuping Zeng

The decomposition characteristics of a SF6 gas-insulated medium were used to diagnose the partial discharge (PD) severity in DC gas-insulated equipment (DC-GIE). First, the PD characteristics of the whole process were studied from the initial PD to the breakdown initiated by a free metal particle defect. The average discharge magnitude in a second was used to characterize the PD severity and th...

Babak Omidvar, Ramin Azizi Yasser abdollahi

Power networks are among the most important infrastructures that without them, industrial, economic and social procedures will halt. Therefore, they should be planned for the most difficult conditions to provide services with minimum disruption. Power substations are of great importance to a power network, because any disruption in their components can produce extensive problems through the net...

2012
Pedro J. Martínez-Lacañina José L. Martínez-Ramos Alfonso Bachiller-Soler

In this paper, educational software for the reliability assessment of high/medium-voltage (HV/MV) substations and distribution feeders is presented. It is a useful tool for learning the utility of reliability indices of the HV/MV substations and their distribution feeders, and their influence on the electrical power system operation. By means of an interactive graphical interface, multiple conf...

2004
Fredrik Wernstedt Paul Davidsson

We present results from an experiment where the effects of automatic flow control at a single substation is compared to automatic cooperative concurrent flow control at multiple substations. The latter approach is made possible by equipping individual substations with some computing power and integrating them into a communications network. Software agents, whose purpose is to cooperate with oth...

2015
Ju Tang Ran Zhuo DiBo Wang JianRong Wu XiaoXing Zhang

With changes in insulated defects, the environment, and so on, new partial discharge (PD) data are highly different from the original samples. It leads to a decrease in on-line recognition rate. The UHF signal and pulse current signal of four kinds of typical artificial defect models in gas insulated switchgear (GIS) are obtained simultaneously by experiment. The relationship map of ultrahigh f...

2004
Fredrik Wernstedt

We present results from experiments where the effects of flow control at a single substation are compared to distributed flow control at multiple substations. The latter approach is made possible by equipping individual substations with some computing power and integrating them into a communications network. Software agents, who cooperate with other software agents (substations) and invoke time...

Journal: :IEEJ Transactions on Power and Energy 1996

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید