نتایج جستجو برای: gas compressibility factor

تعداد نتایج: 1081427  

2005
Alexandre Caboussat Marco Picasso Jacques Rappaz

A model for the simulation of complex three-dimensional free surface flows is presented. An incompressible liquid interacts with a compressible gas. The incompressible Navier-Stokes equations are solved only in the liquid domain while the dynamical effects in the gas are neglected. The compressibility effects of the gas are taken into account by computing its pressure. Surface tension effects a...

1996
Atsushi Yamagata

We perform Monte Carlo simulations of the hard-sphere lattice gas on the body-centred cubic lattice with nearest neighbour exclusion. We get the critical exponents, β/ν = 0.311(8) and γ/ν = 2.38(2), where β, γ, and ν are the critical exponents of the staggered density, the staggered compressibility, and the correlation length, respectively. The values of the hard-sphere lattice gas on the simpl...

2009
Xiaoli Liu Peter Flemings

[1] During sea-level drop, water and gas pressures within oceanic hydrate systems can exceed the total vertical stress and this can drive slope failure and gas venting. We investigate this behavior with a multi-phase fluid and heat flow model. During sea-level drop, fluid pressures drop much less than the total stress due to both the high gas compressibility and hydrate dissociation. In permeab...

Journal: :Langmuir : the ACS journal of surfaces and colloids 2016
Vitaly B Svetovoy Ivan Dević Jacco H Snoeijer Detlef Lohse

In gas-oversaturated solutions, stable surface nanobubbles can exist thanks to a balance between the Laplace pressure and the gas overpressure, provided the contact line of the bubble is pinned. In this article, we analyze how the disjoining pressure originating from the van der Waals interactions of the liquid and the gas with the surface affects the properties of the surface nanobubbles. From...

Journal: : 2021

Oil compressibility represents a significant character in reservoir simulation, design of surface facilities and the analysis well tests, specifically for systems below bubble point pressure.
 is not directly measured laboratory. It usually gained indirectly from experimental data recorded PVT reports. The relative volume flash test used to calculate oil at pressures above pressure. At poi...

2008
Benjamin Paul Michael Schulz Harry L. Frisch

A phantom network of Gaussian chains far from the point of gelation can be described as a gas of interacting particles represented by the cross links. The type of particles varies with the network functionality, whereas the type of interaction depends on the properties of the connecting chains. In a mean field approximation the Equation of State can be calculated using Mayer’s cluster expansion...

2000
D J Purdy

A non-linear model of an adjustable automotive damper is developed, which includes the compressibility of the ̄uid, trapped gas and expansion of the cylinder. The parameters for the model are selected by ®tting the model to experimentally obtained data from the damper. The model is shown to give an excellent representation of the damper under investigation. The performance of the damper model i...

Journal: :iranian journal of chemistry and chemical engineering (ijcce) 1991
a. boushehri ali maghari

the thermal diffusion factor, at, for a binary gas mixture is calculated on the basis of nonequilibrium thermodynamics. a new formula for at is derived and this factor is given for several paris of gases according to this formula.

Journal: :Physical review. E, Statistical, nonlinear, and soft matter physics 2002
Hervé M Carruzzo Clare C Yu

We introduce a structural quantity to probe the glass transition. This quantity is a linear generalized compressibility which depends solely on the positions of the particles. We have performed a molecular dynamics simulation on a glass-forming liquid consisting of a two-component mixture of soft spheres in three dimensions. As the temperature is lowered (or as the density is increased), the ge...

Guaifenesin, a highly water-soluble active (50 mg/mL), classified as a BCS class I drug.Owing to its poor flowability and compressibility, formulating tablets especially high-dose one,may be a challenge. Direct compression may not be feasible. Bilayer tablet technology appliedto Mucinex®, endures challenges to deliver a robust formulation. To overcome challengesinvolved in bilayer-tablet manufa...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید