نتایج جستجو برای: gafchromic film ebt2

تعداد نتایج: 90993  

Journal: :iranian journal of radiation research 0
i. setilo medical physics department, faculty of health sciences, university of the free state, bloemfontein 9300, south africa f.c.p. du plessis medical physics department, faculty of health sciences, university of the free state, bloemfontein 9300, south africa

background:  radiochromic film is used for radiation dose measurement, xr-rv3 is used in fluoroscopy and ebt2 film in radiation therapy. the aim was to determine if the dosimetric properties of these two films are comparable in megavolt photon beams. materials and methods: comparison measurements included: calibration curves, heterogeneous phantom dose profiles, and nasopharynx dose distributio...

2007
Martina Fuss Eva Sturtewagen Carlos De Wagter Dietmar Georg

The suitability of radiochromic EBT film was studied for high-precision clinical quality assurance (QA) by identifying the dose response for a wide range of irradiation parameters typically modified in highly-conformal treatment techniques. In addition, uncertainties associated with varying irradiation conditions were determined. EBT can be used for dose assessment of absorbed dose levels as we...

2017
Grzegorz Zwierzchowski Grzegorz Bieleda Janusz Skowronek

Background Fast and easily repeatable methods for commissioning procedures for brachytherapy (BT) treatment planning systems (TPS) are needed. Radiochromic film dosimetry with gamma analysis is widely used in external beam quality assurance (QA) procedures and planar film dosimetry is also increasingly used for verification of the dose distribution in BT applications. Using the gamma analysis m...

2016
Sandra Sarmento Joana Pereira Maria José Sousa Luís Cunha Anabela G. Dias Miguel F. Pereira Augusto D. Oliveira João V. Cardoso Luís M. Santos Margarida Gouvêa Joana Lencart João G. Alves João A.M. Santos

Computed tomography fluoroscopy (CTF) is a useful imaging technique to guide biopsies, particularly lung biopsies, but it also has the potential for very high hand exposures, despite use of quick-check method and needle holders whenever feasible. Therefore, reliable monitoring is crucial to ensure the safe use of CTF. This is a challenge, because ring dosimeters monitor exposure only at the bas...

Journal: :Medical physics 2005
Alexandra Rink I Alex Vitkin David A Jaffray

A new radiochromic film, GafChromic EBT, was investigated for use in a real-time radiation dosimetry system. It was found to be approximately eight times more sensitive to ionizing radiation dose, exhibited less postexposure development and achieved stable readout faster than one of its predecessors, GafChromic MD-55. A clear distinction in change in optical density between exposure and postexp...

2013
Daniela D’Alessio Claudia Giliberti Antonella Soriani Livio Carpanese Giuseppe Pizzi Giulio Eugenio Vallati Lidia Strigari

PURPOSE The purpose of this study is to evaluate the radiation dose in patients undergoing liver angiographic procedure and verify the usefulness of different dose measurements to prevent deterministic effects. Gafchromic film, MicroMOSFET data and DIAMENTOR device of the X-ray system were used to characterize the examined interventional radiology (IR) procedure. MATERIALS AND METHODS A liver...

Journal: :Medical physics 2013
M Carroll G Ibbott M Gillin J Adamovics

PURPOSE This investigation studies the feasibility of PRESAGE, a 3D polyurethane dosimeter, for relative dosimetry measurements of clinically relevant proton treatments using an anthropomorphic head phantom developed by the Radiological Physics Center (RPC). Performance of a low-LET dependent PRESAGE was evaluated by comparison to the traditionally used radiochromic film, EBT2, and thermolumine...

Journal: :International Journal of Chemical Engineering and Applications 2013

2002
Nobuteru NARIYAMA Yoshihito NAMITO Syuichi BAN

Introduction Recently, owing to the increase of synchrotron radiation facilities such as SPring-8, dose measurements of high-intense low-energy photons are increasingly needed for radiation protection and medical researches. For the dose measurement, tissue equivalence of dosimeter material becomes important. A radiochromic film that has sensitivity in the dose region of several Gy to 100 Gy ha...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید