نتایج جستجو برای: epid

تعداد نتایج: 673  

Journal: :Structure 2000
A Albert M Martínez-Ripoll A Espinosa-Ruiz L Yenush F A Culiáñez-Macià R Serrano

BACKGROUND The Arabidopsis thaliana HAL3 gene product encodes for an FMN-binding protein (AtHal3) that is related to plant growth and salt and osmotic tolerance. AtHal3 shows sequence homology to ScHal3, a regulatory subunit of the Saccharomyces cerevisae serine/threonine phosphatase PPz1. It has been proposed that AtHal3 and ScHal3 have similar roles in cellular physiology, as Arabidopsis tran...

Journal: :Medical physics 2012
B King P Greer

PURPOSE To develop a method for removing the effect of support arm backscatter from Varian electronic portal imaging devices (EPIDs), improving the dosimetric abilities of the imager. METHODS A physical, kernel based model of the backscatter signal produced during an exposure was developed. The model parameters were determined through an optimization process, comparing measured images without...

2018
Bin Cai S. Murty Goddu Sridhar Yaddanapudi Douglas Caruthers Jie Wen Camille Noel Sasa Mutic Baozhou Sun

Normalize the response of electronic portal imaging device (EPID) is the first step toward an EPID-based standardization of Linear Accelerator (linac) dosimetry quality assurance. In this study, we described an approach to generate two-dimensional (2D) pixel sensitivity maps (PSM) for EPIDs response normalization utilizing an alternative beam and dark-field (ABDF) image acquisition technique an...

Journal: :Medical physics 2015
C Bojechko E C Ford

PURPOSE To quantify the ability of electronic portal imaging device (EPID) dosimetry used during treatment (in vivo) in detecting variations that can occur in the course of patient treatment. METHODS Images of transmitted radiation from in vivo EPID measurements were converted to a 2D planar dose at isocenter and compared to the treatment planning dose using a prototype software system. Using...

Journal: :Juntendo Medical Journal 2022

Objectives To develop a method for detecting jaw positions during jaw-tracking delivery to ensure an accurate of radiation patients using electronic portal imaging device (EPID) in the cine mode on linear accelerator radiotherapy.

Journal: :Acta crystallographica. Section D, Biological crystallography 2003
Michael Blaesse Thomas Kupke Robert Huber Stefan Steinbacher

MrsD from Bacillus sp. HIL-Y85/54728 is a member of the HFCD (homo-oligomeric flavin-containing Cys decarboxylases) family of flavoproteins and is involved in the biosynthesis of the lantibiotic mersacidin. It catalyses the oxidative decarboxylation of the C-terminal cysteine residue of the MrsA precursor peptide of mersacidin, yielding a (Z)-enethiol intermediate as the first step in the forma...

2010
Andrea Fidanzio Francesca Greco Alessandra Mameli Luigi Azario Mario Balducci Maria Antonietta Gambacorta Vincenzo Frascino Savino Cilla Domenico Sabatino Angelo Piermattei

An electronic portal imaging device (EPID) is an effective detector for in vivo transit dosimetry. In fact, it supplies two-dimensional information, does not require special efforts to be used during patient treatment, and can supply data in real time. In the present paper, a new procedure has been proposed to improve the EPID in vivo dosimetry accuracy by taking into account the patient setup ...

2011
Indra J. Das Minsong Cao Chee‐Wai Cheng Vladimir Misic Klaus Scheuring Edmund Schüle Peter A.S. Johnstone

Electronic portal imaging device (EPID) plays an important role in radiation therapy portal imaging, geometric and dosimetric verification. Consistent image quality and stable radiation response is necessary for proper utilization that requires routine quality assurance (QA). A commercial 'EPID QC' phantom weighing 3.8 kg with a dimension of 25 × 25 × 4.8 cm³ is used for EPID QA. This device ha...

2008
Rao F.H. Khan Orest Z. Ostapiak Joe J. Szabo

Quality assurance (QA) of an intensity-modulated radiation therapy (IMRT) plan is more complex than that of a conventional plan. To improve the efficiency of QA, electronic portal imaging devices (EPIDs) can be used. The major objective of the present work was to use a commercial treatment planning system to model EPID response for the purpose of pre-treatment IMRT dose verification. Images wer...

Journal: :Radiation Oncology (London, England) 2009
Marco Krengli Simone Gaiano Eleonora Mones Andrea Ballarè Debora Beldì Cesare Bolchini Gianfranco Loi

BACKGROUND The reproducibility of patient setup for radiotherapy is based on various methods including external markers, X-rays with planar or computerized image acquisition, and, more recently, surface matching imaging. We analyzed the setup reproducibility of 16 patients affected by prostate cancer who underwent conformal radiotherapy with curative intent by using a surface image registration...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید