نتایج جستجو برای: dosimetric characteristics monte carlo simulation

تعداد نتایج: 1231401  

Journal: :international journal of communications and information technology 0
m. soroosh shahid chamran university m. a. mansouri-birjandi university of sistan and baluchestan

in this paper, we calculate electron and hole impactionization coefficients in in0.52al0.48as using a monte carlo modelwhich has two valleys and two bands for electrons and holesrespectively. also, we calculate multiplication factor for electronand hole initiated multiplication regimes and breakdown voltagein in0.52al0.48as pin avalanche photodiodes. to validate themodel, we compare our simulat...

Journal: :iranian journal of medical physics 0
m. t. bahreyni toosi professor, medical physics research center, bu-ali research institute, mashhad university of medical sciences, mashhad, iran. m. momen nezhad ph.d. student in medical physics, mashhad university of medical sciences, mashhad, iran h. saberi ph.d. student in medical physics, mashhad university of medical sciences, mashhad, iran m. h. bahreyni toosi professor, medical physics research center, bu-ali research institute, mashhad university of medical sciences, mashhad, iran. a. hashemian assistant professor, medical physics research center, bu-ali research institute, mashhad university of medical sciences, mashhad, iran. r. salek assistant professor, radiation oncology dept., imam reza hospital, mashhad university of medical sciences, mashhad, iran.

ntroduction:  monte  carlo  simulation  is  the  most  accurate  method  of  simulating  radiation  transport  and  predicting doses at different points of interest in radiotherapy. a great advantage of the monte carlo method  compared  to  the  deterministic  methods  is  the  ability  to  deal  accurately  with  any  complex  geometry.  its  disadvantage is the extremely long computing time r...

Journal: :journal of biomedical physics and engineering 0
f seif arak university of medical sciences m r bayatiani arak university of medical sciences

background: megavoltage beams used in radiotherapy are contaminated with secondary electrons. different parts of linac head and air above patient act as a source of this contamination. this contamination can increase damage to skin and subcutaneous tissue during radiotherapy.  monte carlo simulation is an accurate method for dose calculation in medical dosimetry and has an important role in opt...

Journal: :physical chemistry research 0
hamed moradmand jalali department of physical chemistry, faculty of chemistry, university of kashan, iran

kinetic monte carlo simulation was applied to investigation of kinetics and mechanism of oxalic acid degradation by direct and heterogeneous catalytic ozonation. la-containing perovskites including lafeo3, lanio3, lacoo3 and lamno3 was studied as catalyst for oxalic acid ozonation. the reaction kinetic mechanisms of each abovementioned catalytic systems has been achieved. the rate constants val...

2003
S. Chick P. J. Sánchez D. Ferrin Brenda McCabe

Research was undertaken to assist practitioners in undertaking Monte Carlo simulation of project schedules. A probabilistic model was developed to translate project characteristics into schedule risk boundaries. This model has been tested in several projects and performed very well. Lessons learned during the application of Monte Carlo simulation to a large project are discussed.

Journal: :Applied Psychological Measurement 1983

Journal: :Nuclear technology 2009
Pablo Yepes Sharmalee Randeniya Phillip J Taddei Wayne D Newhauser

Monte Carlo codes are utilized for accurate dose calculations in proton radiation therapy research. While they are superior in accuracy to commonly used analytical dose calculations, they require significantly longer computation times. The aim of this work is to characterize a Monte Carlo track-repeating algorithm to increase computation speed without compromising dosimetric accuracy. The track...

H. Gholamhoseinian, M. Momennezhad, M.T. Bahreyni Toosi, R. Sadeghi, Sh. Nasseri,

Background: The presence of a wedge filter in the beam trajectory can modify the beam quality and cause some changes in the dosimetry parameters which are usually difficult to be measured directly and accurately. Material and Methods: In this study the MCNP-4C Monte Carlo code was used to simulate the 9 MV photon beam generated by a linear accelerator. Upon getting a good agreement bet...

Journal: :iranian journal of medical physics 0
zohreh dehghannia rostami graduated m.sc. student of nuclear physics, physics dept., kn toosi university of technology, tehran, iran. seyed farhad masoudi associate professor, physics dept., kn toosi university of technology, tehran. iran somayeh asadi graduated m.sc. student of nuclear physics, physics dept., kn toosi university of technology, tehran, iran.

introduction: in this paper, by complete definition of human eye containing the various parts and their materials, the difference between this model and a homogeneous water phantom are compared for two ophthalmic plaques using 125i and 103pd. material and methods: the simulation of the two phantoms were performed in the mcnp-4c code and by using the geometry of a three-dimensional eye, differen...

Journal: :iranian journal of chemistry and chemical engineering (ijcce) 2009
bahman abdolhamidzadeh davood rashtchian elham ashuri

some of the most destructive accidents of 1980s and 90s which occurred in process industries were domino accidents. although domino accidents are among the most destructive industrial accidents, there are not much pioneering works done on quantification of them. the analytical formulation of the domino accidents is usually complex and need a deep knowledge of probability rules. even if the case...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید