Journal: :Photochemical & photobiological sciences : Official journal of the European Photochemistry Association and the European Society for Photobiology 2005
A V Parisi M G Kimlin D J Turnbull J Macaranas

The research reported in this paper on the changes in absorbance and the calibration of a proposed UVA (320-400 nm) dosimeter have established the phenothiazine-mylar combination as a potential UVA dosimeter for population studies of UVA exposures. The change in optical absorbance at 370 nm was employed to quantify the UVA exposures. This change starts to saturate at a change in absorbance of a...

2001
Sara Olsson Eva S. Bergstrand

Journal: :Nuclear Instruments and Methods 1959

2012
B. Azadbakht

The purpose of this study was to evaluate dependence of PAGAT polymer gel dosimeter 1/T2 on different electron and photon energies for a standard clinically used Co therapy unit and an electa linear accelerator.Using MRI, the formulation to give the maximum change in the transverse relaxation rate R2(1/T2) was determined to be 4.5% N,N'-methylen-bis-acrylamide(bis), 4.5% acrylamid(AA), 5% gelat...

Journal: :The European respiratory journal 2000
H C Siersted C M Walker A D O'Shaughnessy A R Willan E M Wiecek M R Sears

In the European Community Respiratory Health Study (ECRHS), airway responsiveness to methacholine was determined using the Mefar dosimeter protocol. Elsewhere, the 2-min tidal breathing method has become the preferred standardized method. The relationship between measurements of responsiveness by these two methods is not well established. This study measured airway responsiveness to methacholin...

2006
Alfio V. Parisi Michael G. Kimlin

Polysulphone has been widely used as a dosimeter to quantify personal solar UV exposures to humans during normal daily activities. In summer at sub-tropical and tropical latitudes, the dynamic range for UV exposures allows the use of the polysulphone to measure solar UV over periods of approximately three to six hours. The use of mesh as a filter over the polysulphone has been previously report...

2013
C - S Wuu Y Xu X Qian J Adamovics E Cascio

Monte Carlo water-equivalence study of two PRESAGE® formulations for proton beam dosimetry T Gorjiara, Z Kuncic, J Adamovics and C Baldock 2013 J. Phys.: Conf. Ser. 444 012090 PRESAGE® is a radiochromic solid dosimeter which shows promising potential for 3D proton beam dosimetry. Since an idea dosimeter should be water-equivalent, total depth dose distributions in two PRESAGE® formulations irra...

2008
J. B. Davies C. Baldock

Spectrophotometric measurements of the Fricke–gelatin–xylenol orange (FGX) gel dosimeter demonstrated reproducible linear dose response up to 25Gy. However, oxidation processes continue post-irradiation, affecting the response of this dosimetry system. Additional oxygenation during preparation increases the sensitivity of the gel but does not improve the auto-oxidation stability of the dosimete...

Journal: :iranian journal of medical physics 0
mohammad amin mosleh-shirazi 1- center for research in medical physics and biomedical engineering, shiraz university of medical sciences, shiraz, iran 2- physics unit, department of radiotherapy and oncology, namazi hospital, shiraz university of medical sciences, shiraz, iran sareh karbasi physics unit, department of radiotherapy and oncology, namazi hospital, shiraz university of medical sciences, shiraz, iran reza faghihi department of medical radiation and radiation research center, school of mechanical engineering, shiraz university, shiraz, iran

introduction radiotherapy planning systems require many percentage depth dose (pdd) and profile measurements and there are various dosimeters that can be used to obtain these scans. as dose perturbation is particularly troublesome in smaller photon fields, using a low-perturbation, unshielded electron field diode (efd) in these fields is of interest. the aim of this work was to investigate the ...