نتایج جستجو برای: dielectric measurement
تعداد نتایج: 478173 فیلتر نتایج به سال:
This paper presents the results of an investigation on the effect of a thin low-dielectric material (phantom shell) on measuring the Specific Absorption Rate (SAR) in the frequency range of 3 to 6 GHz. The International Electrotechnical Commission (IEC) has started to develop a SAR measurement procedure in order to cover such frequencies. In the procedure, the SAR is measured in a liquid phanto...
High temperature operating life (HTOL) testing was performed on embedded planar capacitors (with epoxyBaTiO3 composite dielectric) by subjecting these devices to highly accelerated temperature and voltage aging conditions. The objective of HTOL testing was to precipitate avalanche breakdown failures as a result of defects in the composite dielectric. These defects include porosity, voids, and a...
Evaluation of Diffusion-Driven Material Property Profiles Using Three-Wavelength Interdigital Sensor
The response of a three-wavelength interdigital dielectrometry sensor to the moisture diffusion process in oil-impregnated transformer pressboard has been simulated using an empirical relationship between the moisture concentration and the dielectric properties of the pressboard. A benchmark test of the moisture diffusion process has been developed with the purpose of comparing alternative para...
In this paper a Frequency Selective Surface (FSS) as a UWB electromagnetic shield is introduced. The proposed FSS comprises a quasi-J.C-Jerusalem Cross- and a copper ring, which are located at both sides of a FR4 substrate and can represent a S.E -Shielding Effectiveness- better than 20dB in 90% bandwidth of Ultra Wide Band frequency. This structure is compact and thin. Each cell comprises J.C ...
Knowledge of the dielectric properties of commodities and insect pests is important in developing thermal treatments for postharvest insect control based on radio frequency (RF) and microwave energy. The dielectric properties of six subtropical and tropical fruits along with four associated insect pests were measured between 1 and 1800 MHz using an open-ended coaxial-line probe technique and at...
The complex dielectric constants at room temperature of various goat tissues (liver, muscle, kidney, heart and brain) and corn syrup were measured in the frequency range 1 to 10 GHz with the help of a HP Network Analyzer N5230A. Open ended coaxial cable method was employed for the measurement. The system imperfections are completely avoided by calibrating the system with four known materials an...
Microwave absorbing property of composites containing Ag nanoparticles filled multiwalled carbon nanotube buckypaper (Ag-BP) has been investigated. Buckypaper doped with silver was prepared by direct dispersion and filtration method. From the low temperature resistivity measurement it was found that increasing doping level decreases the electrical conductivity of the buckypaper. 30 wt. % and 40...
A noninvasive, in situ calibration method for total internal reflection microscopy (TIRM) based on optical tweezing is presented, which greatly expands the capabilities of this technique. We show that by making only simple modifications to the basic TIRM sensing setup and procedure, a probe particle's absolute position relative to a dielectric interface may be known with better than 10 nm preci...
The penetration depth ( ) dependence on temperatures for high superconducting YBa2Cu3O7 thin films stored in various environments was measured by a well-designed microwave dielectric resonator. A -wave 2 dependence was observed at low temperatures, while an exponential dependence of the penetration depth ( ) relevant to the wave was detected as temperature increases due to thermal fluctuation. ...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید