نتایج جستجو برای: developed three longitudinal mode heterodyne interferometer dtlmi
تعداد نتایج: 2217013 فیلتر نتایج به سال:
We demonstrate an active laser heterodyne interferometer which can automatically compensate environmental disturbances and is capable of precision displacement measurement. Two Zeeman He-Ne lasers were employed. Laser II was used as the light source to stabilize the interferometer by using a piezomirror in a feedback loop. The hetereodyne signal of the two lasers was used to directly calibrate ...
Optical-heterodyne measurements are made on ~842-nm signal output of an injection-seeded optical parametric oscillator (OPO) based on periodically poled KTiOPO4 pumped at 532 nm by long (~27-ns) pulses from a Nd:YAG laser. At low pump energies (</= 2.5 times the free-running threshold), the narrowband tunable OPO output is single-longitudinal-mode (SLM) and frequency chirp can be <10 MHz, much ...
Laser frequency noise is a significant noise source which couples into the main science measurement of the Laser Interferometer Space Antenna via the mismatch between the interferometer arm lengths. In this paper we discuss the application of an unequal pathlength heterodyne Mach–Zehnder interferometer to measure and actively stablize the master laser frequency as used in LISA Pathfinder. In co...
We perform 3D cross-correlation measurements of the optical field distribution resulting from an ultrashort pulse propagating in 6 meters of multimode fiber. Spatial amplitude and phase distributions of the optical field at the output of the fiber are measured using a time-gated spatial heterodyne interferometer as a function of time delay between the signal and the reference optical fields. We...
We present results on the frequency stabilization of two diode-laser-pumped ring lasers that are independently locked to the same high-finesse interferometer. We measure the relative frequency stability by locking the lasers one free spectral range apart and observing the heterodyne beat note. The resultant beat note width of 2.9 Hz is consistent with the theoretical system noise-limited linewi...
This paper presents a heterodyne common-path grating interferometer with Littrow configuration (HCGIL). The HCGIL can effectively overcome environmental disturbance effect and the DC offset and the amplitude variation of the measurement signals. Experimental results match well with the HP5529A results for long-range measurements. Results also show that the estimated measurement resolution is 0....
Electronic heterodyne moire deflectometry and electronic heterodyne holographic interferometry are compared as methods for the accurate measurement of refractive index and density change distributions of phase object p . Experimental results are presented to show that the two methods have comparable accuracy for measuring the first derivative of the intE-ferometric fringe shift. The phase objec...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید