نتایج جستجو برای: collimator detector response
تعداد نتایج: 1033857 فیلتر نتایج به سال:
In this paper, a new method for measuring the neutron flux using proportional counters SNM-18 filled with 3Ne is studied. When developing equipment automated measurement of research reactor VVR-K, determining optimization criteria are power consumption, weight and dimensions. For purpose, devices were used equivalent soil moisture snow water by component cosmic rays. A number experimental studi...
Abstract X-rays spectroscopy experiments at synchrotron facilities were limited for many years by the maximum input count rate and signal-to-background ratio of germanium fluorescence detectors. These limitations are related to semiconductor device, sensor configuration its response incident X-ray flux different energies. In order understand quantify such limitations, physics simulation detecto...
Evaluation of the scattered radiation components produced in a gamma camera using Monte Carlo method
Introduction: This paper presents a simulation for evaluation of the scattered radiation components produced in a gamma camera PARK using Monte Carlo code SIMIND. It simulates a whole body study with MDP (Methylene Diphosphonate) radiopharmaceutical based on Zubal anthropomorphic phantom, with some spinal lesions. Methods: The simulation was done by comparing 3 configurations for the detected p...
This work describes preliminary test studies with a dual-headed SPECT system that utilizes a new generation of silicon double-sided strip detectors (DSSDs) (Figure 1) with a 1-mm bulk thickness and larger active area (60 × 60 mm) as compared to standard gamma-ray silicon detectors. Furthermore, major improvements in the ASIC design make this detector very suitable for low-energy imaging of smal...
PURPOSE Stereotactic radiosurgery/therapy (SRS/SRT) is the use of radiation ablation in place of conventional surgical excision to remove or create fibrous tissue in small target volumes. The target of the SRT/SRS treatment is often located in close proximity to critical organs, hence the requirement of high geometric precision including a tight margin on the planning target volume and a sharp ...
Background: In high-intensity, mixed and pulsed neutron fields the use of spectrometers or area monitors with active detectors is useless in these conditions neutron measuring devices must have a passive detector. Here a passive neutron area monitor with CR39 track detector was designed and the response was calculated. Materials and Methods: The response of a passive neutron area monitor with C...
Several groups have reported the development of dual modality Gamma camera/optical imagers, which are useful tools for investigating biological processes in experimental animals. While previously reported dual modality imaging instrumentation usually employed a separated gamma camera and optical imager, we designed a detector using a position sensitive photomultiplier tube (PSPMT) that is capab...
MEDISIP, Department of Electronics and Information Systems, Ghent University-iMinds Medical ITIBiTech, Ghent, Belgium Digital photon counters (DPC, Philips Digital Photon Counting) are compact photon detectors that are promising for the design of a compact SPECT insert for MRI. Given the small bore of most preclinical MR scanners such an insert has to fulfil strict space constraints. In DPCs th...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید