نتایج جستجو برای: coated platinum electrode

تعداد نتایج: 129157  

A fiber coating from polyaniline (PANI) was electrochemically prepared and employed for Solid phase micreoextraction (SPME). The PANI film was directly electrodeposited on the platinum wire surface using cyclic voltametry (CV) technique. The same method was applied for the preparation of SPME fiber coated by polyaniline multiwalled carbon nanotubes (PANI/MWCNTs) composite. The concentration of ...

1999
Frank G. Gao Allen J. Bard Lowell D. Kispert

Photocurrent was observed upon monochromatic illumination of an ITO electrode coated with a TiO2 nanocrystalline mesoporous membrane with carotenoid 8′-apo-b-caroten-8′-oic acid (ACOA) deposited as a sensitizer (illuminated area 0.25 cm2) and immersed in an aqueous 10 mM hydroquinone (H2Q), 0.1 M NaH2PO4 solution (pH = 7.4) purged with argon, using a platinum flag counter electrode (area 3.3 cm...

Journal: :British heart journal 1963
P G Nixon G A Hay F Hepburn H M Snow R Addyman

In 1960 Leland Clark reported his discovery that the concentration of ascorhic acid injected into the blood stream could be measured continuously with a platinum electrode and amperometric apparatus. His communication was important because it gave cardiologists an innocuous indicator and a simple method for recording dilution curves within the circulation. The principle of the method is that a ...

Journal: :Journal of controlled release : official journal of the Controlled Release Society 2010
André Mercanzini Sai T Reddy Diana Velluto Philippe Colin Anne Maillard Jean-Charles Bensadoun Jeffrey A Hubbell Philippe Renaud

Controlled release coatings were developed for neuroprostheses with the aim of combating the tissue reaction following implantation in the brain. The coatings consist of poly(propylene sulfide) drug-eluting nanoparticles embedded in a poly(ethylene oxide) matrix. The nanoparticles are loaded with dexamethasone, an anti-inflammatory drug known to have an effect on the cells activated during the ...

Journal: :AJNR. American journal of neuroradiology 2005
Gádor Cantón David I Levy Juan C Lasheras

BACKGROUND AND PURPOSE The purpose of this study was to measure the changes in the intraaneurysmal fluid pressure and parent vessel flow characteristics resulting from packing the aneurysmal sac with hydrogel-coated coils. METHODS Platinum coils coated with an expansible hydrogel were used to embolize a silicone model of the basilar tip aneurysm. The intraaneurysmal fluid pressure was measure...

Journal: :Chemphyschem : a European journal of chemical physics and physical chemistry 2010
Leah A Riley Andrew S Cavanagh Steven M George Yoon Seok Jung Yanfa Yan Se-Hee Lee Anne C Dillon

An alumina surface coating is demonstrated to improve electrochemical performance of MoO(3) nanoparticles as high capacity/high-volume expansion anodes for Li-ion batteries. Thin, conformal surface coatings were grown using atomic layer deposition (ALD) that relies on self-limiting surface reactions. ALD coatings were tested on both individual nanoparticles and prefabricated electrodes containi...

Journal: :journal of physical and theoretical chemistry 0
mohammad yari not-mentioned sajjad sedaghat sherehjini not-mentioned

the electrocatalysis of the oxygen reduction reaction (orr) on carbon supportedpt-v (1:1) catalyst in polymer electrolyte fuel cells (pefc) was investigated. atan oxygen pressure of one atm an enhanced electrocatalytic property of pt-v/ccompared with pt/c is revealed. these results indicate the occurrence of adifferent electrocatalytic mechanism for the orr on pt/c and pt-v/c. anincrease of mas...

Journal: :Analytical chemistry 2005
Darren A Walsh José L Fernández Janine Mauzeroll Allen J Bard

The fabrication and characterization of novel micropipet probes for use in scanning electrochemical microscopy (SECM) are described. These can be used to dispense small (pL) amounts of a solution while monitoring the electrochemical response at a substrate and at a ring electrode tip on the micropipet probe. The probes were constructed by insulating gold-coated borosilicate micropipets with ele...

Journal: :The Journal of chemical physics 2015
Marco Bonetti Sawako Nakamae Bo Tao Huang Thomas J Salez Cécile Wiertel-Gasquet Michel Roger

A thermally chargeable capacitor containing a binary solution of 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)-imide in acetonitrile is electrically charged by applying a temperature gradient to two ideally polarisable electrodes. The corresponding thermoelectric coefficient is -1.7 mV/K for platinum foil electrodes and -0.3 mV/K for nanoporous carbon electrodes. Stored electrical en...

2010
Karl Maurer Nina Yazvenko Jodi Wilmoth John Cooper Wanda Lyon David Danley

The CombiMatrix microarray with 12,544 electrodes supports in situ electrochemical synthesis of user-defined DNA probes. As an alternative, we immobilized commercially synthesized DNA probes on individual electrodes coated with electropolymerized polypyrrole (Ppy). Hybridization was measured using a biotinylated target oligonucleotide and either Cy5-streptavidin and fluorescence detection or ho...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید