نتایج جستجو برای: chemical dosimeter

تعداد نتایج: 379992  

2006
Alfio V. Parisi Michael G. Kimlin

Polysulphone has been widely used as a dosimeter to quantify personal solar UV exposures to humans during normal daily activities. In summer at sub-tropical and tropical latitudes, the dynamic range for UV exposures allows the use of the polysulphone to measure solar UV over periods of approximately three to six hours. The use of mesh as a filter over the polysulphone has been previously report...

2013
C - S Wuu Y Xu X Qian J Adamovics E Cascio

Monte Carlo water-equivalence study of two PRESAGE® formulations for proton beam dosimetry T Gorjiara, Z Kuncic, J Adamovics and C Baldock 2013 J. Phys.: Conf. Ser. 444 012090 PRESAGE® is a radiochromic solid dosimeter which shows promising potential for 3D proton beam dosimetry. Since an idea dosimeter should be water-equivalent, total depth dose distributions in two PRESAGE® formulations irra...

2008
J. B. Davies C. Baldock

Spectrophotometric measurements of the Fricke–gelatin–xylenol orange (FGX) gel dosimeter demonstrated reproducible linear dose response up to 25Gy. However, oxidation processes continue post-irradiation, affecting the response of this dosimetry system. Additional oxygenation during preparation increases the sensitivity of the gel but does not improve the auto-oxidation stability of the dosimete...

Journal: :The Journal of the Acoustical Society of America 2012
Steven Ryherd Mendel Kleiner Kerstin Persson Waye Erica E Ryherd

In recent years, interest in personal noise exposure has expanded beyond a workplace safety measure to become an effective means of investigating physiological effects of the acoustic environment on an individual. This work investigates the effects of the wearer's voice as a possible dominant sound source on body-mounted noise dosimeters and develops methods to improve the application of dosime...

Journal: :Journal of the Ceramic Society of Japan 2013

Journal: :Radiation Physics and Chemistry 2021

Noting an increase in demand for procedures involving clinical radiosurgery we seek to develop a high spatial resolution thermoluminescence dosimeter (TLD) allow conduct of vivo dose verification measurements. An associated need is dynamic range exceeding that the well-established LiF (Mg,Ti) phosphor TLD-100, with particular latter being limited performance at elevated doses seen radiotherapy....

Journal: :Brazilian Journal of Radiation Sciences 2023

Radiation dosimetry has the purpose of quantifying dose received by occupationally exposed individual. The device used in this process is called a dosimeter, dosimeter can be different situations, for example, to quantify fingers ring model extremity, which focus work. In Brazil, we still do not have standards calibration extremity dosimeters, therefore, work, CASEC recommendations were used, a...