نتایج جستجو برای: beamline

تعداد نتایج: 2367  

2012
Alan Kastengren Christopher F. Powell Dohn Arms Eric M. Dufresne Harold Gibson Jin Wang

In recent years, X-ray radiography has been used to probe the internal structure of dense sprays with microsecond time resolution and a spatial resolution of 15 µm even in high-pressure environments. Recently, the 7BM beamline at the Advanced Photon Source (APS) has been commissioned to focus on the needs of X-ray spray radiography measurements. The spatial resolution and X-ray intensity at thi...

Journal: :Journal of synchrotron radiation 2004
R Fischetti S Stepanov G Rosenbaum R Barrea E Black D Gore R Heurich E Kondrashkina A J Kropf S Wang Ke Zhang T C Irving G B Bunker

The 18ID undulator beamline of the Biophysics Collaborative Access Team at the Advanced Photon Source, Argonne, IL, USA, is a high-performance instrument designed for, and dedicated to, the study of partially ordered and disordered biological materials using the techniques of small-angle X-ray scattering, fiber diffraction, and X-ray absorption spectroscopy. The beamline and associated instrume...

Journal: :Journal of synchrotron radiation 2006
Gerd Rosenbaum Randy W Alkire Gwyndaf Evans Frank J Rotella Krzystof Lazarski Rong Guang Zhang Stephan L Ginell Norma Duke Istvan Naday Jack Lazarz Michael J Molitsky Lisa Keefe John Gonczy Larry Rock Ruslan Sanishvili Martin A Walsh Edwin Westbrook Andrzej Joachimiak

The 19ID undulator beamline of the Structure Biology Center has been designed and built to take full advantage of the high flux, brilliance and quality of X-ray beams delivered by the Advanced Photon Source. The beamline optics are capable of delivering monochromatic X-rays with photon energies from 3.5 to 20 keV (3.5-0.6 A wavelength) with fluxes up to 8-18 x 10(12) photons s(-1) (depending on...

2015
F. D’ACAPITO A. TRAPANANTI

This document presents the refurbishment project for GILDA, the Italian CRG beamline at the ESRF. After a short introduction to the beamline and its achievements in the last years, the base ideas and concepts driving the design are exposed whereas a more detailed technical description of the new instrument is given in a further section. An analysis of the costs and a schedule for the implementa...

2011
Carmelo Prestipino Olivier Mathon Ricardo Hino Antonia Beteva Sakura Pascarelli

The new implementation of QEXAFS acquisition on the general purpose EXAFS beamline BM29 at the European Synchrotron Radiation Facility is presented. By adopting a continuous-scan mode, a high signal-to-noise ratio can be maintained, together with a fixed exit beam and full compatibility with step-by-step operation, while reducing acquisition times to a few seconds. The new equipment implemented...

2013

In section 1.1 we detail the experimental setup used at the SXR beamline of the Linac Coherent Light Source. This is followed by section 1.2 detailing the sample preparation and the x-ray characterization performed at beamline 13-3 of the Stanford Synchrotron Radiation Lightsource. In section 1.3 we detail how spin sensitivity is achieved in resonant x-ray scattering and subsequently in section...

Journal: :Acta crystallographica. Section F, Structural biology and crystallization communications 2012
Arne Meyer Karsten Dierks Dierk Hilterhaus Thomas Klupsch Peter Mühlig Jens Kleesiek Robert Schöpflin Howard Einspahr Rolf Hilgenfeld Christian Betzel

A completely new crystal-growth device has been developed that permits charting a course across the phase diagram to produce crystalline samples optimized for diffraction experiments. The utility of the device is demonstrated for the production of crystals for the traditional X-ray diffraction data-collection experiment, of microcrystals optimal for data-collection experiments at a modern micro...

Journal: :Acta crystallographica. Section D, Structural biology 2016
Armin Wagner Ramona Duman Keith Henderson Vitaliy Mykhaylyk

Structure solution based on the weak anomalous signal from native (protein and DNA) crystals is increasingly being attempted as part of synchrotron experiments. Maximizing the measurable anomalous signal by collecting diffraction data at longer wavelengths presents a series of technical challenges caused by the increased absorption of X-rays and larger diffraction angles. A new beamline at Diam...

2011
Marc Allaire Lin Yang

In recent years there has been a growing interest in the application of X-ray scattering techniques to biomolecules in solution. At NSLS, a new undulator-based beamline, X9, has been constructed to address the oversubscribed user demand for X-ray scattering. Beamline X9 has the capability to perform small/wide-angle X-ray scattering (SAXS/WAXS) all in one single instrument. This is accomplished...

Journal: :Journal of synchrotron radiation 2002
Timothy M McPhillips Scott E McPhillips Hsiu-Ju Chiu Aina E Cohen Ashley M Deacon Paul J Ellis Elspeth Garman Ana Gonzalez Nicholas K Sauter R Paul Phizackerley S Michael Soltis Peter Kuhn

The Blu-Ice and Distributed Control System (DCS) software packages were developed to provide unified control over the disparate hardware resources available at a macromolecular crystallography beamline. Blu-Ice is a user interface that provides scientific experimenters and beamline support staff with intuitive graphical tools for collecting diffraction data and configuring beamlines for experim...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید