نتایج جستجو برای: alternate refrigerant

تعداد نتایج: 26364  

Journal: :gas processing 0
mostafa mafi department of mechanical engineering, imam khomeini international university, qazvin, iran bahram ghorbani department of energy system engineering k.n.toosi gholam reza salehi energy system engineering department, k. n. toosi university of technology, iran majid amidpour k. n. toosi university of technology seyed mojtaba mousavi nayenian energy system engineering department, k. n. toosi university of technology, iran

a refrigeration cycle is a chain of various pieces of equipment including compressors, condensers, evaporators, and expansion devices each of which takes on a particular thermodynamic process duty in the cycle that eventually results in the production of the required refrigeration. the results of optimized mixed refrigerant cycles (mrcs) in part i show that the configuration of mrc is an effect...

2014
K. W. Yun

The rotary compressor accumulator with pre-charged oil has already been developed and the concept published.[I] Compared to the conventional accumulator, the new accumulator differentiates itself from the conventional one in that the new accumulator is pre-charged with a pre-determined amount of oil. It offers advantages as a conventional accumulator attached to rotary compressor. This paper no...

2014
M. Takeuchi H. Kobayashi K. Sato M. Fujitani N. Hayashi H. Machida

This paper presents the development of the low cost liquid pump. The rotary compressor developed as the gas compressor for the residential air-conditioner was converted into the liquid refrigerant pump. Problems of the liquid refrigerant pump are the reliability assessment of sliding parts and the reduction of the noise generated by discharge pulsation in this development. Therefore some modifi...

2013
Abhishek Kumar

This paper presents the experimental performance analysis of a window air conditioner using two refrigerants R22 and R410A.The effect of the different parameters of performance analysis (refrigeration capacity, COP, compressor power ,pressure ratio ) were investigated for various evaporating temperature and ambient temperature. .The result shows that refrigerant R22 is better than R410A in case...

2017
Christopher R. Laughman Hongtao Qiao Daniel J. Burns Scott A. Bortoff

While the mass of refrigerant contained in a vapor compression cycle has a significant effect on the cycle’s power consumption, conventional cycle architectures cannot optimize energy efficiency by varying the mass as ambient conditions and operational requirements change. This paper proposes a new system architecture that allows the refrigerant mass circulating in the system to be modulated ov...

2014
G. H. Goble George B. Goble

There currently exists a large number (millions) of automobiles with air conditioning systems designed to use CFC-12 as the refrigerant along with plans to produce ~uch systems into the 1992-1995 time frame. During the 1992-1995 period, new production will transition to HFC-134a refrigerant based systems or other technologleS which offer zero or llttle ozone depletion. CFC-12 based systems will...

2014
M. G. Smith S. P. Lepper Mark G. Smith

Typical automotive air conditioning refrigeration systems employ thermostatic expansion valve or orifice tube controls in a single stage refrigerant circuit. A new automotive air conditioning compressor has been developed that has a two stage compression process, which makes designing and producing a two stage refrigerant circuit more practical. Since this compressor can function in a single st...

Journal: :physical chemistry and electrochemistry 0
seyyed mostafa hoseini young researchers and elite club, marvdasht branch, islamic azad university, marvdasht, iran

the present work is the successful extension of an improved equation of state (eos) to refrigerant fluids. the objective is the prediction of isothermal and saturated liquid densities of refrigerants. two temperature-independent parameters appearing in the modified eos are closely related to critical point properties of refrigerant fluids. our results showed that, the proposed eos can predict w...

Journal: :physical chemistry and electrochemistry 0
p khorramzadeh department of chemistry, marvdasht branch, islamic azad university, marvdasht, iran nima karachi department of chemistry, marvdasht branch, islamic azad university, marvdasht, iran seyyed mostafa hosseini young researchers and elite club, marvdasht branch, islamic azad university, marvdasht, iran

an analytical equation of state has been previously modified by papari et al. for representing the volumetric properties of molecular fluids. however the performance of that eos has not been yet well investigated for refrigerant fluids. this study extended that equation to 19 liquid refrigerants to predict their densities at isothermal and saturated states. two temperature-independent parameter...

2014
K. H. Lee J. W. Kim Y. J. Huh J. Lee Janghee Lee

Present study is undertaken to optimize the lubrication reliability and frictional loss of the dynamically-loaded jownal bearing with R600a refrigerant application. A mathematical model is developed for analyzing the dynamics of the journal bearing system with the mobility method. It takes into account the effects of the refrigerant species, aspect ratio, clearance ratio and surface roughness. ...