2014

KORESPONDENCIJA / CORRESPONDENCE Authors report the case of a 59-year old woman with bilateral posterior lens luxation in vitreous, medically controlled glaucoma and corneal adherent leucoma with vascularization in whom Marfan syndrome was diagnosed. e patient underwent complete clinical eye and systemic examinations and blood samples were drawn for mutational screening of €brillin1 gene (FBN1...

2010
Vishnu S Gupta Harinder S Sethi Malvika Gupta Anuj Mehta Shivram Singh Pankaj Yadav KPS Malik

BACKGROUND To describe, a yet non-documented complication of GDI surgery (glaucoma drainage incision surgery)--anterior to posterior segment migration of Ahmed Glaucoma Valve (AGV) tube. CASE PRESENTATION We report a young 9 year old boy, diagnosed with refractory glaucoma with Reiger anomaly. History included of poor vision in both eyes, left more than right with glare since childhood. He un...

2014
Minwen Zhou Wei Wang Wenbin Huang Xiulan Zhang

BACKGROUND To evaluate the surgical outcome of Ahmed glaucoma valve (AGV) implantation with a new technique of mitomycin C (MMC) application. METHODS This is a retrospective study. All patients with refractory glaucoma underwent FP-7 AGV implantation. Two methods of MMC application were used. In the traditional technique, 6 × 4 mm cotton soaked with MMC (0.25-0.33 mg/ml) was placed in the imp...

2016
Rui B Schimiti Ricardo Y Abe Carla M Tavares Jose PC Vasconcellos Vital P Costa

AIM To evaluate the results of Ahmed glaucoma valve (AGV) in eyes with a failed trabeculectomy. MATERIALS AND METHODS This retrospective study evaluated 61 eyes with a failed trabeculectomy that underwent implantation of an AGV due to uncontrolled intraocular pressure (IOP) on maximal medical therapy. Success was defined as IOP ≤ 21 mm Hg (criterion 1) or 20% reduction in IOP (criterion 2) wi...

Journal: :Chang Gung medical journal 2003
Shiu-Chen Wu Samuel C M Huang Ken-Kuo Lin

BACKGROUND To assess clinical outcomes of the Ahmed glaucoma valve implant, an aqueous shunting device with a unidirectional valve mechanism, in eyes with refractory glaucoma. METHODS Consecutive patients with intractable glaucoma who underwent Ahmed glaucoma valve insertion were retrospectively reviewed. Only patients with a minimum of 6 months of follow-up were included. The presence of int...

2015
Avik Kumar Roy Sirisha Senthil

INTRODUCTION Glaucoma in aphakia is a major long term complication following congenital cataract surgery. Implantation of glaucoma drainage device provides an effective approach to manage refractory paediatric glaucoma. However implant surgery in young individuals is not free of complications. The prompt detection and management of tube erosion is of utmost importance to prevent devastating seq...