نتایج جستجو برای: admittance control

تعداد نتایج: 1330787  

2017
Quan Liu Aiming Liu Wei Meng Qingsong Ai Sheng Quan Xie

Traditional compliance control of a rehabilitation robot is implemented in task space by using impedance or admittance control algorithms. The soft robot actuated by pneumatic muscle actuators (PMAs) is becoming prominent for patients as it enables the compliance being adjusted in each active link, which, however, has not been reported in the literature. This paper proposes a new compliance con...

2004
S. Thwaites

The admittance o• a turbulent jet as the generator in organ flue pipes was investigated experimentally with respect o the relevant parameters, that is, the frequency, the jet effiux velocity, the mouth end-correction, and the jet tip deflection at the cdge. First, an experiment was performed using a jet with a pulsating velocity to drive a pipe to isolate and identify the various drive mechanis...

2016
Dawei Liu Bo Cheng Xiaotian Pan Lifang Qiao

A new method of designing horn-fed frequency scanning holographic antenna is proposed. The artificial surface design of holographic antenna is based on generalized law of reflection. The input admittance is utilized to construct the interference pattern of the surface which is intervened by the excitation wave and the required radiation wave. The scalar admittance unit cell which is composed of...

2017
Lennart Harnefors Alejandro G. Yepes

The interconnection stability of a grid-connected voltage-source converter (VSC) can be assessed by the passivity properties of the VSC input admittance. If critical grid resonances fall within regions where the input admittance acts passively, i.e., has nonnegative real part, then their destabilization is generally prevented. This paper presents an overview of passivity-based stability assessm...

2016
Matej Voglar Jeffrey Wamerdam Idsart Kingma Nejc Sarabon Jaap H van Dieën

The goal of the present study was to determine the effects of prolonged, intermittent flexion on trunk neuromuscular control. Furthermore, the potential beneficial effects of passive upper body support during flexion were investigated. Twenty one healthy young volunteers participated during two separate visits in which they performed 1 hour of intermittent 60 seconds flexion and 30 seconds rest...

2004
T. K. Bose

Several formulas for the calculation of the admittance of open-ended coaxial probes from the complex permittivity, E, of the measured medium and the dimensions of the probe are presented. The inverse problem, calculation of c from the measured admittance of the probe, is also studied in detail. These formulas are discussed and compared in terms of numerical calculations. New universal diagrams ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید