نتایج جستجو برای: activating agents and monte carlo code

تعداد نتایج: 16886189  

Journal: :journal of biomedical physics and engineering 0
t raj verma n kumar painuly s prasad mishra s a yoganathan n singh m l b bhatt

background: the dosimetric parameters required in lung cancer radiation therapy are taken from a homogeneous water phantom; however, during treatment, the expected results are being affected because of its inhomogeneity. therefore, it becomes necessary to quantify these deviations. objective: the present study has been undertaken to find out inter- and intra- lung density variations and its dos...

Journal: :iranian journal of medical physics 0
asghar mesbahi department ofmedical physics, medical school, tabriz university of medical sciences,,tabriz, iran. 2- department ofradiation oncology, imam hospital, tabriz, iran. ismail zergoug 3-department of radiotherapy, emir abdelkaderanti-cancer center, oran, algeria

introduction radiotherapy with small fields is used widely in newly developed techniques. additionally, dose calculation accuracy of treatment planning systems in small fields plays a crucial role in treatment outcome. in the present study, dose calculation accuracy of two commercial treatment planning systems was evaluated against monte carlo method. materials and methods siemens once or linea...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه شهید چمران اهواز - دانشکده ادبیات و علوم انسانی 1386

the purpose of the present study is to find out whether bilinguals of khuzestan-arab origin or monolinguals of iranian origin code-switch during learning or speaking english and which group is more susceptible to code-switch. to this end, the students of 24 classes from high schools and pre- university centers were screened out, and interviewed and their voices and code-switchings were recorded...

Journal: :journal of biomedical physics and engineering 0
f seif arak university of medical sciences m r bayatiani arak university of medical sciences

background: megavoltage beams used in radiotherapy are contaminated with secondary electrons. different parts of linac head and air above patient act as a source of this contamination. this contamination can increase damage to skin and subcutaneous tissue during radiotherapy.  monte carlo simulation is an accurate method for dose calculation in medical dosimetry and has an important role in opt...

2016
Ryan C. Bleile Patrick S. Brantley Shawn A. Dawson Matthew J. O’Brien Hank Childs

Power consumption considerations are driving future high performance computing platforms toward many-core computing architectures. The Trinity machine to become available at Los Alamos National Laboratory in 2016 will use both Intel Xeon Haswell processors and Intel Xeon Phi Knights Landing many integrated core (MIC) architecture coprocessors. The Sierra machine to be available at Lawrence Live...

A. Antoniadis, J.G. Fantidis,

Background: A Boron Neutron Capture Therapy (BNCT) facility, based on a DT neutron generator, with the final goal to find out a potential, alternative, solution to existing BNCT treatment facilities which are based on nuclear reactors is examined. Materials and Methods: With the aim of the MCNP4B Monte Carlo code different beam-shaping assembly (BSA) configurations were considered. Lead was sel...

Journal: :iranian journal of radiation research 0
j.g. fantidis department of electrical engineering, kavala institute of technology, greece e. saitioti department of electrical engineering, kavala institute of technology, greece d.v. bandekas department of electrical engineering, kavala institute of technology, greece n. vordos department of electrical engineering, kavala institute of technology, greece

background: boron neutron capture therapy (bnct) is a very promising treatment for patients suffering gliobastoma multiforme, an aggressive type of brain cancer, where conventional radiation therapies fail. thermal neutrons are suitable for the direct treatment of cancers which are located at near-tissue-surface deep-seated tumors need harder, epithermal neutron energy spectra. materials and me...

انتظار مهدی, محمد, خم خاجی, جمال, قدیری, حسین , مجرد کاهانی, محمد مهدی , هاشمی, سمانه, کمالی اصل, علیرضا ,

Background and purpose: Dual-energy mammography is a technique which is used to enhance the accuracy of breast cancer diagnosis especially in dense breasts. This study was conducted based on the simultaneous use of two contrast agents for automatic separation and also to evaluate their accuracy using dual-energy digital mammography. Materials and methods: A breast phantom was designed and b...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید