نتایج جستجو برای: 03 and zero mm

تعداد نتایج: 16858456  

Mycorrhizal fungi symbiosis with plants root through effective uptake of water and nutrients can be reduced the negative effects of salinity. To evaluate the effect of mycorrhizal fungi on some morpho-physiological traits and yield of Summer savory a greenhouse factorial experiment was conducted based on randomized complete block design with three replications at the Laboratory of Medicinal Pla...

ژورنال: دانشور پزشکی 2013
خلیل‌پور, محمد , سالاری, علی محمد , شایق, سید شجاع الدین ,

 Background and Objective: Using 2 implants in edentulous lower jaw is a standard protocol treatment for improvement of prosthesis retention. Different attachments have been produced in factories. One of these attachments is locator that is now a famous clinical option. In this in vitro study, the effect of inter implant distance on retention in simulated function condition and on 2 bra...

H. Al-Attas M. A. Bokhari

Orthogonal zero interpolants (OZI) are polynomials which interpolate the “zero-function” at a finite number of pre-assigned nodes and satisfy orthogonality condition. OZI’s can be constructed by the 3-term recurrence relation. These interpolants are found useful in the solution of constrained approximation problems and in the structure of Gauss-type quadrature rules. We present some theoretical...

Germination and seedling establishment are sensitive and important stages in the life cycle of plants that are affected by abiotic stresses, especially drought and salinity stresses. This study was conducted to investigate the effects of osmotic potential (due to sodium chloride and polyethylene glycol) on germination and biochemical indices of Salicornia sinus-persica Akhani spec. nov.Akhani s...

Journal: :international journal of mathematical modelling and computations 0
m. a. bokhari kfupm, dhahran saudi arabia deptartment of mathematics & statatistic h. al-attas kfupm, dhahran saudi arabia deptartment of mathematics & statatistic

orthogonal zero interpolants (ozi) are polynomials which interpolate the “zero-function” at a finite number of pre-assigned nodes and satisfy orthogonality condition. ozi’s can be constructed by the 3-term recurrence relation. these interpolants are found useful in the solution of constrained approximation problems and in the structure of gauss-type quadrature rules. we present some theoretical...

2003
J GAJDOŠ KLJUSURIĆ

This work is an experimental study of the differential scanning calorimetry characterisation of polymer materials used in food packaging materials, such as polypropylene (0·03 mm), polyethylene (0·1 and 0·03 mm), poly(D-(-)-β-hydroxybutyrate) (powder), two-layered polypropylene (0·064 mm), and two-layered polypropylene with poly-vinylidene-chloride (0·012/0·021). The polymer stability was check...

Journal: :Ultrasonics 2004
Stephen D Holland D E Chimenti

The well known zero in the group velocity of the first-order symmetric (S1) plate wave mode has been exploited in air-coupled ultrasonic imaging to obtain significantly higher sensitivity than can be achieved in conventional air-coupled scanning. At the zero group velocity point at the frequency minimum of the S1 mode, a broad range of wavenumbers couple into the first-order symmetric mode at n...

.Salt stress is one of the major abiotic stresses especially in arid and semi-arid regions. This investigation was conducted to evaluate the effects of the salt stress on Ascorbate Peroxidase (APX) and Superoxide Dismutase (SOD) activities in safflower genotypes based in on a factorial experiment as a Completely Randomized Design (CRD) with three replications. The experimental factors were six ...

2012
S. Das R. K. Nayak G. N. Dash A. K. Panda

The electrical properties characterization of AlGaN/GaN based Modulation Doped Field Effect Transistor (MODFET) is reported. Threshold voltage Vth=-3.87 V, maximum saturation current Idss=122.748 mA, gate-source capacitance at zero gate voltage and also maximum gate-source capacitance= 0.161753 pF/μm, gate-source capacitance=0.157233 pF/μm at Id=0.3Idss, trans-conductance (gm) = 31.3806 mS/mm a...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید