[ 1 ] - A New Strategy for Simultaneous Compensation of Instantaneous Reactive Power and Harmonics of Non-Linear Loads (RESEARCH NOTE)

This paper presents a new control method for simultaneous compensation of instantaneous reactive power and current harmonics by parallel active filters (PAFs). Reference compensating currents of PAF are calculated using the subtraction of instantaneous power from its average value. In this way, it is possible omitting high/low pass filter(s) from the control circuit of PAF, which usually result...

[ 2 ] - Dynamic Compensation of Electrical Power Systems Using Multilevel Voltage Source Inverter

A New Static Var Generator (SVG), using cascaded full-bridge inverters (FBI) with binary output levels and the parallel connections of two cascaded inverters by means of current sharing reactor in each phases is introduced. The new M-level inverter, where M is 2n+2 - 3, consists of only 2n single-phase full bridges for each phases. The proposed technique not only increases the current capacity ...

[ 3 ] - Neural Network Implementation of a Three Phase Regulated PWM AC to Dc Convener with Input Unbalance Correction

Under unbalanced supply condition low order harmonics will appear at the input and output terminals of the PWM AC to DC converter. Based on the positive and negative sequence components, an unbalanced transfer matrix in terms of the input phase voltages is derived. An on-line method using a neural network (NN) is used to implement this transfer matrix. It is shown that by using an additional lo...

[ 4 ] - Transient Minimization Within Static Var Compensated Distribution Systems

VAR support should be supplied as close to the load as possible to minimize transmission losses. For voltage control and for improvement of total power factor in a distribution system the circuit- breaker switched capacitor banks can be used. The problems with this solution are the voltage steps caused by the large sizes of the capacitor banks as well as the transients caused on insertion. Thyr...

[ 5 ] - A Non-Sinusoidal Reference Wave for Pwm Ac Drives

In this paper we propose a suitable reference wave for Pulse Width Modulation (PWM) AC Drives. Staircase reference waves whose levels are calculated to eliminate certain harmonics are studied and a certain staircase reference waveform with L levels is constructed. When L is made very large in limit, this staircase waveform approaches a continuous one which is called Quasine (Quasi + Sine). This...

[ 6 ] - New Methods for Harmonic Reduction in T. C. R. by Sequence Control of Transformer Taps

Thyristor controlled static compensators consist of two basic schemes, TCR and TSC. Owing to the discontinuous current in TCR, current harmonics are generated in the supply system. This paper introduces two methods for the reduction of these harmonics. On the basis of the coordination or uncoordination of turn ratios with harmonic reduction levels, each method is described in two alternative sc...