Bilal Yilmaz
Department of Analytical Chemistry, Faculty of Pharmacy, Ataturk University, 25240, Erzurum, Turkey
[ 1 ] - Stability Indicating HPLC Method for the Determination of Fulvestrant in Pharmaceutical Formulation in Comparison with Linear Sweep Voltammetric Method
This paper describes two rapid, sensitive and specific methods for the determination of fulvestrant in pharmaceutical preparations by high performance liquid chromatography (HPLC) and linear sweep voltammetry (LSV). HPLC method was used to study the degradation behaviour. Fulvestrant was subjected to degradation under the conditions of hydrolysis (acid and alkali), oxidation (30% H2O2). The lin...
[ 2 ] - Square Wave Voltammetric Determination of Diclofenac in Pharmaceutical Preparations and Human Serum
In this study, a simple and reliable square wave voltammetric (SWV) method was developed and validated for determination of diclofenac in pharmaceutical preparations and human serum. The proposed method was based on electrooxidation of diclofenac at platinum electrode in 0.1 M TBAClO4/acetonitrile solution. The well-defined two oxidation peaks were observed at 0.87 and 1.27 V, respectively. Cal...
[ 3 ] - Determination of Bosentan in Pharmaceutical Preparations by Linear Sweep, Square Wave and Differential Pulse Voltammetry Methods
In this study, simple, fast and reliable cyclic voltammetry (CV), linear sweep voltammetry (LSV), square wave voltammetry (SWV) and differential pulse voltammetry (DPV) methods were developed and validated for determination of bosentan in pharmaceutical preparations. The proposed methods were based on electrochemical oxidation of bosentan at platinum electrode in acetonitrile solution containin...
[ 4 ] - Stability Indicating HPLC Method for the Determination of Fulvestrant in Pharmaceutical Formulation in Comparison with Linear Sweep Voltammetric Method
This paper describes two rapid, sensitive and specific methods for the determination of fulvestrant in pharmaceutical preparations by high performance liquid chromatography (HPLC) and linear sweep voltammetry (LSV). HPLC method was used to study the degradation behaviour. Fulvestrant was subjected to degradation under the conditions of hydrolysis (acid and alkali), oxidation (30% H2O2). The lin...
[ 5 ] - Square Wave Voltammetric Determination of Diclofenac in Pharmaceutical Preparations and Human Serum
In this study, a simple and reliable square wave voltammetric (SWV) method was developed and validated for determination of diclofenac in pharmaceutical preparations and human serum. The proposed method was based on electrooxidation of diclofenac at platinum electrode in 0.1 M TBAClO4/acetonitrile solution. The well-defined two oxidation peaks were observed at 0.87 and 1.27 V, respectively. Cal...
[ 6 ] - Determination of Bosentan in Pharmaceutical Preparations by Linear Sweep, Square Wave and Differential Pulse Voltammetry Methods
In this study, simple, fast and reliable cyclic voltammetry (CV), linear sweep voltammetry (LSV), square wave voltammetry (SWV) and differential pulse voltammetry (DPV) methods were developed and validated for determination of bosentan in pharmaceutical preparations. The proposed methods were based on electrochemical oxidation of bosentan at platinum electrode in acetonitrile solution containin...
نویسندگان همکار