Using electrochemical impedance spectroscopy of salicylate anion selective electrode: simulation for behavior of electrode

نویسندگان

  • A. DEHGHAN MANSHADI Payame Noor University, I. R. Iran
  • H. AZIZI Taft Branch, Islamic Azad University, I. R. Iran
  • M. MAZLOUM-ARDAKANI Yazd University, I. R. of Iran
  • S. MOZAFFARI Iranian Research Organization for Science & Technology (IROST),, I. R. Iran
چکیده مقاله:

In this paper, the behavior of the salicylate anion-selective electrode was studied using the electrochemical impedance spectroscopy technique. Considering the diagram of the charge transfer resistance and -logarithm of the double layer capacitance versus -logarithm of the concentration, linear range concentration increased to 1.0×10^{-8}-1.0×10^{-1} M and 1.0×10^{-9}-1.0×10^{-1} M, respectively. Among the other characteristics of this study, it can be pointed out a wide pH range of 4.0-10.0. Then "one-impedance for one-concentration" method was used to measure the salicylate ion at the linear range of 1.0×10^{-8}-1.0×10^{-1} M. Finally, the impedance spectra of this electrode were simulated in which the obtained results of this simulation indicate proximity of experimental and simulation data.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reducing Impedance Fluctuation by Electrode Structure for Electrochemical Impedance Spectroscopy

In this paper, we investigated the electrode structure of the electrical bio-sensor to reduce impedance measurement fluctuation. Five pairs of the same electrodes were formed on the PCB substrate, and a fluidic channel was constructed with a double-sided tape and polycarbonate cover so that all the electrodes had the same reagent distribution. In order to find an electrode structure with little...

متن کامل

Characterization of coplanar electrode structures for microfluidic-based impedance spectroscopy

Impedance spectroscopy has the potential for label-free integrated electrochemical detection in microfluidic lab-on-a-chip applications. Its capability to identify and discern between surface and bulk processes in solid-liquid systems finds particular use for the detection of biorecognition events or conductivity measurements. The electrochemical transducer can be in the form of interdigitated ...

متن کامل

Selective Electrochemical Nanosensor based on Modified Carbon Paste Electrode for Determination of NADH in the presence of Uric Acid

The electrochemical properties of a modified carbon paste electrode with the synthesized compound of 2,2'-[1,7–heptanediylbis(nitrilomethylidene)]-bis(4-hydroxyphenol) (DHBH) and graphite nanoparticle (GN) were studied by cyclic voltammetry (CV), chronoamperometry and differential pulse voltammetry (DPV) methods. The proposed electrode shows excellent electrocatalytic activity towards the oxida...

متن کامل

Real-time measurement of electrode impedance during intracochlear electrode insertion.

OBJECTIVES/HYPOTHESIS This pilot study details the use of a software tool that uses continuous impedance measurement during electrode insertion, with the eventual potential to assess and optimize electrode position and reduce insertional trauma. STUDY DESIGN Software development and experimental study with human cadaveric cochleae and two live surgeries. METHODS A prototype program to measu...

متن کامل

Electrochemical Behavior of Copper Electrode in Potassium Sulfide Solutions

The electrochemical behavior of copper electrode in 2M potassium sulfide solution was studied using cyclic voltammograms and potentiostatic polarization techniques. The morphology studies were applied using scanning electron microscope (SEM) and energy dispersive analysis of X-rays (EDAX) and X-ray powder diffraction. Three anodic peaks were observed in the anodic scan of cyclic voltammograms. ...

متن کامل

Electrochemical adsorptive behavior of some fluoroquinolones at carbon paste electrode.

Cyclic voltammetry and differential pulse voltammetry were used to explore the adsorption behavior of three antibacterial agents at a carbon paste electrode. The drugs were accumulated on a carbon paste electrode, and a well-defined oxidation peak was obtained in acetate buffer (pH 5.0). The adsorptive stripping response was evaluated as a function of some variables such as the scan rate, pH an...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 4  شماره 1

صفحات  41- 57

تاریخ انتشار 2013-03-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023