Upgrading the Seismic Capacity of Pile-Supported Wharfs Using Semi-Active Liquid Column Gas Damper
نویسنده
چکیده مقاله:
One of the most important structures in the ports is the wharf. The most common one is the pile-supported wharf. This type of wharf is consisted of a number of piles and one deck which placed on the piles. In addition to the conventional loads that this structure should withstand, in seismic areas, pile-supported wharfs should have the necessary capacity and strength against seismic excitations. There are some approaches to increase the seismic capacity of the berth. One of these methods is to control the vibrations of the pile-supported wharf against earthquake loads using a damper. In this research, for the first time, a new semi-active damper called the semi active liquid column gas damper (SALCGD), was used to reduce the response of pile supported wharf under seismic loads. In the first step by applying different records of the earthquake, the most important parameter of this damper - the optimal opening ratio of the horizontal column- was obtained for this particular structure. In the following, the performances of this damper and its comparison with the tuned liquid column gas damper (TLCGD) were discussed. This study showed that the use of this semi-active damper (SALCGD) reduces the displacement of the pile-supported wharf by 35% and reduces the acceleration of the structure by 50% on average. In contrast, the passive damper (TLCGD) reduces the displacement of about 20 percent and the acceleration of about 30 percent. Therefore, it was observed that the semi-activation of the damper (SALCGD) had a significant improvement in its performance in controlling the vibrations of pile-supported wharf.
منابع مشابه
Seismic Bearing Capacity of Strip Footings on Pile-Stabilized Slopes
This paper develops an analytical method to calculate seismic bearing capacity of a strip footing, which is located on a slope reinforced with rows of pile. The resistance of passive pile is determined based on normal and shear stress of the soil around the pile, which is then compared to other analytical methods. This comparison indicates an acceptable agreement. The variants of the study incl...
متن کاملTitle Semi-active suspension with semi-active inerter and semi-active damper
This paper investigates the application of semi-active inerter in semi-active suspension. A semi-active inerter is defined as an inerter whose inertance can be adjusted within a finite bandwidth by on-line control actions. A force-tracking approach to designing semi-active suspension with a semi-active inerter and a semi-active damper is proposed, where the target active control force derived b...
متن کاملAssessment of Semi-Active Tunes Mass Damper Application in Suppressing Seismic-Induced Vibration of an Existing Jacket Platform
In this study, mass, stiffness and damping matrices of the Nosrat jacket; located in Persian Gulf; equipped with Semi Active Tuned Mass Damper (SATMD) system have been derived after modeling the structure in SACS software. Owing to huge number of the degrees of freedom in the model, computation of on-line control of SATMD was time consuming. For this purpose, the size of the model was reduced i...
متن کاملSemi-active suspension with semi-active inerter and semi-active damper ⋆
This paper investigates the application of semi-active inerter in semi-active suspension. A semi-active inerter is defined as an inerter whose inertance can be adjusted within a finite bandwidth by on-line control actions. A force-tracking approach to designing semi-active suspension with a semi-active inerter and a semi-active damper is proposed, where the target active control force derived b...
متن کاملFuzzy Control of Seismic Structure with an Active Mass Damper
Fuzzy theory is highly promising for active structural control. The advantage of fuzzy controllers over classical controllers is the limited number of measured structural responses used to implement the control rules and its intrinsic robustness. In this paper, Fuzzy rules were generated firstly by learning from sample data obtained from the performance of the system under optimal control algor...
متن کاملGas holdup in a gas-liquid-fiber semi-batch bubble column
A 4-m high, 15.24-cm diameter semi-batch bubble column connected to one of three perforated plate gas distributors with open area ratios A = 0.57%, 0.99%, and 2.14% is employed to study gas holdup and flow regime in Rayon and Nylon fiber suspensions. This study determines the effect of superficial gas velocity, fiber type, fiber mass fraction, fiber length, and aeration plate open area ratio on...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 6 شماره 1
صفحات 112- 124
تاریخ انتشار 2020-01-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
کلمات کلیدی
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023