Translation, Validity, and Reliability of the Upper Extremity Fugl-Meyer Assessment (FMA-UE) in Persian Speaking Stroke Patients
نویسندگان
چکیده مقاله:
Objectives: Fugl-Meyer Assessment (FMA) is the common scale for clinical and functional evaluation of sensorimotor conditions and related Upper Extremity (UE) dysfunction after stroke. This study was done to translate and cross-culturally adjust the original upper extremity FMA (FMA-UE) into Persian and to evaluate the psychometric properties of the translated version. Methods: A procedure of forward/backward translation based on the published guidelines was adopted and two independent bilingual translators performed the translations in each stage. The conceptual and semantic equivalence was obtained through a consensus between experts. Consecutive stroke patients (n=47, male=63%) with a mean age of 61.54±10.9 years were recruited. Content, face, and concurrent validity was calculated using the content validity index, a cognitive interview, and correlation with the Wolf Motor Function Test (WMFT). Internal consistency and intra-rater reliability were determined by calculating Cronbach’s alpha and the Intra-Class Correlation coefficient (ICC2.1). Results: During the forward translation and cultural adjustment, some wording changes were performed. In the forward translation, the most challenging clarifications are related to anatomical terms and positions. The total FMA-Persian score demonstrated acceptable internal consistency (α=0.86) and intra-rater reliability (ICC2.1=0.96). Joint passive motion showed the lowest reliability among all domains. The FMA motor subscales showed a floor effect, while sensation, joint passive motion, and pain domains showed ceiling effects. The correlation between the FMA-UE score and the WMFT was 0.78 (P<0.001). Discussion: The FMA-UE translation and adjustment were performed successfully into the Persian language. The results of the current study found FMA-UE as an acceptable, reliable, and valid instrument for evaluating the upper limb function after stroke in Persian-speaking patients. However, it should be noted that floor and ceiling effects are respectively present in the domains of the motor subscales and for sensation, passive motion, and pain.
منابع مشابه
The Test-Retest Reliability and Minimal Detectable Change of the Fugl-Meyer Assessment of the Upper Extremity and 9-Hole Pegboard Test in Individuals With Subacute Stroke
Purpose: The first step to manage motor impairment of upper limb in patients with subacute stroke is having an accurate assessment tool. The Fugl-Meyer assessment of upper extremity and 9-hole pegboard test are used to evaluate motor function and hand dexterity in stroke survivals. The present study aimed to investigate the test-retest reliability and minimal detectable change (MDC) in these tw...
متن کاملReliability of the Fugl-Meyer assessment for testing motor performance in patients following stroke.
BACKGROUND AND PURPOSE The purpose of this study was to establish the interrater reliability of assessments made with the Fugl-Meyer evaluation of physical performance in a rehabilitation setting. SUBJECTS Twelve patients (7 male, 5 female), aged 49 to 86 years (mean = 66), who had sustained a cerebrovascular accident participated in the study. All patients were admitted consecutively to a re...
متن کاملthe test-retest reliability and minimal detectable change of the fugl-meyer assessment of the upper extremity and 9-hole pegboard test in individuals with subacute stroke
purpose: the first step to manage motor impairment of upper limb in patients with subacute stroke is having an accurate assessment tool. the fugl-meyer assessment of upper extremity and 9-hole pegboard test are used to evaluate motor function and hand dexterity in stroke survivals. the present study aimed to investigate the test-retest reliability and minimal detectable change (mdc) in these tw...
متن کاملUpper Extremity Functional Evaluation by Fugl-Meyer Assessment Scoring Using Depth-Sensing Camera in Hemiplegic Stroke Patients
Virtual home-based rehabilitation is an emerging area in stroke rehabilitation. Functional assessment tools are essential to monitor recovery and provide current function-based rehabilitation. We developed the Fugl-Meyer Assessment (FMA) tool using Kinect (Microsoft, USA) and validated it for hemiplegic stroke patients. Forty-one patients with hemiplegic stroke were enrolled. Thirteen of 33 ite...
متن کاملTranslating measurement findings into rehabilitation practice: an example using Fugl-Meyer Assessment-Upper Extremity with patients following stroke.
Standardized assessments are critical for advancing clinical rehabilitation, yet assessment scores often provide little information for rehabilitation treatment planning. A keyform recovery map is an innovative way for a therapist to record patient responses to standardized assessment items. The form enables a therapist to view the specific items that a patient can or cannot perform. This infor...
متن کاملTranslation, adaptation and inter-rater reliability of the administration manual for the Fugl-Meyer assessment.
BACKGROUND Recently, the reliability of the Brazilian version of the Fugl-Meyer Assessment (FMA) was assessed through the scoring given according to observations made by a single evaluator who applied the test. When different raters apply the scale, the reliability may depend on the interpretation given to the assessment sheet. In such cases, a clear administration manual is essential for ensur...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 20 شماره March- Special-Issue on Occupational Therapy
صفحات 37- 46
تاریخ انتشار 2022-03
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023