Transient Characteristics of a Single-Effect Absorption Refrigeration Cycle
نویسندگان
چکیده مقاله:
This paper deals with a lumped-parameter dynamic simulation of a single-effect LiBr-H2O absorption chiller. In many studies the thermodynamic properties of LiBr-H2O solution were taken from some approximate relations causing the results to be somewhat inaccurate. These relations were used to solve simultaneous differential equations involving the continuity of species constituting the LiBr-H2O solution, momentum equations, and energy balances. To diminish the effect of these approximate relations on the results, in this study the thermodynamic properties were taken from the EES software. By making a link between EES and MATLAB softwares, the simultaneous differential equations were solved in MATLAB environment and this process was continued until the convergence criterion was satisfied. Moreover, this study considers the effect of quality on the concentration of solution at the exits of generator and absorber. This effect was ignored in the previous works. In other words, the concentrations of solution at the generator and absorber were not assumed to be equal to the corresponding concentration at the exit of those components in this model. Furthermore, a transient analysis of exergy is accomplished. As time passes, both the coefficient of performance and exergetic efficiency decrease, approaching the steady-state values. The results deduced from the dynamic simulation are compared with those in steady-state condition. The comparison shows that the transient simulation predictions are in close agreement with steady-state results.
منابع مشابه
Thermoeconomic Analysis of a Single and Double-Effect LiBr/H2O Absorption Refrigeration System*
The aim of this work is to carry out a thermoeconomic analysis of a single and double-effect LiBr/H2O absorption refrigeration system. The methodology of functional analysis with negentropy is used. The exergetic cost of the main product, the cooling cost, was calculated as a function of the exergy of the heat source. Two cases were analyzed for each system: the first considers a direct-fired s...
متن کاملDevelopment of a Novel Combined Absorption Cycle for Power Generation and Refrigeration
Cogeneration can improve energy utilization efficiency significantly. In this paper, a new ammonia-water system is proposed for the cogeneration of refrigeration and power. The plant operates in a parallel combined cycle mode with an ammonia-water Rankine cycle and an ammonia refrigeration cycle, interconnected by absorption, separation, and heat transfer processes. The performance was evaluate...
متن کاملOptimal Cooling Load and COP Relationship of a Four-Heat-Reservoir Endoreversible Absorption Refrigeration Cycle
Received: 5 April 2004 / Accepted: 14 June 2004 / Published: 15 June 2004 __________________________________________________________________________________ Abstract: On the basis of a four-heat-reservoir endoreversible absorption refrigeration cycle model, another linear heat transfer law [i.e., the heat-flux ) ( 1 − ∆ ∝ T Q ] is adopted, the fundamental optimal relation between the coefficien...
متن کاملExperimental investigation on the effect of phase change materils (PCM) in solar compression refrigeration cycle efficiency
Saving energy is one of the most important challenges of todaychr('39')s world. Reducing electrical energy consumption in compressed air systems is one of the essential requirements for designing these systems. When using domestic air conditioners (dual air conditioners) in very hot areas (Khuzestan) their performance decreases and electric current consumption increases. Therefore, the use of n...
متن کاملThe Effect of Fiber Breakage on Transient Stress Distribution in a Single-Lap Joint Composite Material
In the present study, the transient stress distribution caused by a break in the fibers of an adhesive bonding is investigated. Transient stress is a dynamic response of the system to any discontinuity in the fibers from detachment time till their equilibrium state (or steady state). To derive the governing dynamic equilibrium equations shear lag model is used. Here, it is assumed that the tens...
متن کاملthermoeconomicanalysis andmulti-objectiveoptimization of a libr-water absorption refrigeration system
performance optimization of a single-effect lithium bromide water absorption refrigerationsystem is the subject of this paper. first, the thermodynamic model of the system wasderived based on thefirst and second law analysis of an absorption refrigeration cycle with libr-water as the working fluid pair.then, the effects of different design parameters such as the generator inlet hot water temper...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 2 شماره 4
صفحات 40- 47
تاریخ انتشار 2013-03
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023