Thermal Performance of a Double-pass Solar Air Heater

نویسندگان

  • Abdellah Shafieian Department of Mechanical Engineering, University of Kurdistan, Sanandaj , Kurdistan, Iran
  • Roonak Daghigh Department of Mechanical Engineering, University of Kurdistan, Sanandaj , Kurdistan, Iran
چکیده مقاله:

This study analyzes the thermal performance of solar thermal energy using double-pass absorber plate in Sanandaj, Iran. To this end, a mathematical model was encoded according to the energy and exergy balance equations and solved by MATLAB software. Given the environmental conditions and radiation intensity of a winter day in Sanandaj, the effects of external parameters such as radiation intensity and internal parameters such as canal’s height, inlet mass flow rate, absorber length as well as some physical parameters on the efficiency of the system were analyzed and the energy and exergy output of the system was studied. To validate the proposed model, the results obtained from numerical simulation were compared with experimental data, which showed an acceptable compatibility. Finally, the ability of the system to supply the thermal load of the building in the given day was examined and the roles of various factors in the area under thermal coverage of this system were analyzed. The obtained findings indicated that a system with an area of 3 m2 and mass rate of 250 kg/hr in radiation intensity of 619 W/m2 and temperature of 3.45° is capable of supplying the thermal load of a space with an approximate area of 14 m2.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

performance of a photovoltaic/thermal solar air heater: effect of vertical fins on a double pass system

the steady state effect of vertical fins is assessed on a photovoltaic/thermal solar air heater having a double pass configuration in which fins are placed in the lower channel perpendicular to the direction ofair flow. air passes through the upper channel of the air heater and before passing in the opposite direction through the lower channel. the effects of design, climatic and operating para...

متن کامل

Effect of depth ratio on the thermal performance of double flow packed bed solar air heater

In this paper double flow packed bed solar air heater has been investigated theoretically. The effect of air mass flow rate, porosity and different depth ratios at study state conditions on the thermal performance of a double flow packed bed solar air heater is found by using the alternative simulation system. Comparisons between the measured thermal and effective thermal efficiency of the doub...

متن کامل

Thermal behaviour of solar air heater with compound parabolic concentrator

A mathematical model for computing the thermal performance of an air heater with a truncated compound parabolic concentrator having a flat one-sided absorber is presented. A computer code that employs an iterative solution procedure is constructed to solve the governing energy equations and to estimate the performance parameters of the collector. The effects of the air mass flow rate, the wind ...

متن کامل

Thermal Hydraulic Performance in a Solar Air Heater Channel with Multi V-Type Perforated Baffles

This article presents heat transfer and fluid flow characteristics in a solar air heater (SAH) channel with multi V-type perforated baffles. The flow passage has an aspect ratio of 10. The relative baffle height, relative pitch, relative baffle hole position, flow attack angle, and baffle open area ratio are 0.6, 8.0, 0.42, 60 ̋, and 12%, respectively. The Reynolds numbers considered in the stud...

متن کامل

Experimental study of heat transfer and thermal performance with longitudinal fins of solar air heater

The thermal performance of a single pass solar air heater with five fins attached was investigated experimentally. Longitudinal fins were used inferior the absorber plate to increase the heat exchange and render the flow fluid in the channel uniform. The effect of mass flow rate of air on the outlet temperature, the heat transfer in the thickness of the solar collector, and the thermal efficien...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 3  شماره 2

صفحات  35- 46

تاریخ انتشار 2016-05-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023