Thermal and Surface Changes of Dental Implants Following Use of Rotary Instruments and Piezoelectric Devices for Implantoplasty: An In-Vitro Study

نویسندگان

  • رئوفی, سعید گروه پریودانتیکس
  • عمید, رضا گروه پریودانتیکس
چکیده مقاله:

  Objective: Peri-implantitis is an irreversible inflammatory reaction in the soft and hard tissues around a functional implant . One of the treatment approaches of this disease include smoothing and polishing the rough surface and removing threads on the implants using rotary instruments, which is called implantoplasy. Clinicians should perform implantoplasty with caution because it may raise the temperature of the implant body as well as the surrounding bone . This study aimed to compare micromorphology and thermal changes obtained with different rotary instruments and piezoelectric device after implantoplasty.   Methods: In this in vitro study 48 Intra Lock fixture surfaces were processed in 60 seconds with six polishing procedures using 6,12 bladed carbide burs, 90, 30 µm mean-particles-size diamond burs, and piezosurgery inserts OT1 (grain size= 91 µm) and OP5 (grain size= 30 µm). These instruments were applied in single or sequences procedures. Variations in temperature were recorded every 5 seconds. The roughness of treated surfaces was evaluated with a profilometer for Ra1, Rz1 (single polish procedures), Ra2, and Rz2 (sequence polish procedures) parameters. Also, surfaces were observed using a field emission scanning electron after each step of implantoplasty.   Results: The piezosurgery group showed statistically significant differences with the other two groups ) maximum temperature 1.2 °C ( . No statistically significant differences were observed between the carbide and diamond burs regarding the temperature changes and the temperature decreased from the start point in both groups. The mean Ra value in piezoelectric group (1.53 (0.23)) was significantly lower than diamond (2.45 (0.40), p <0.05 ) and carbide (2.10 (0.28) , p <0.05 ) groups. Besides, this measure in the carbide group was significantly lower than that of the diamond group (p <0.05 ). Rz1 value was significantly greater in diamond and carbide groups compared to piezoelectric group. The results revealed significant differences among the three groups concerning Rz2. The minimum Rz2 value was seen in piezoelectic group, while the diamond group showed the highest Rz2 parameter. Conclusion: This in virto study showed that in suitable cooling conditions, implantoplasty with rotary and piezoelectric devices does not produce excessive heat increases which can damage the soft tissue or bone around the affected implant. The piezoelectric device produced smoother surfaces in single or sequence procedures compared to the burs and can be useful for implantoplasy.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

thermal and surface changes of dental implants following use of rotary instruments and piezoelectric devices for implantoplasty: an in-vitro study

objective: peri-implantitis is an irreversible inflammatory reaction in the soft and hard tissues around a functional implant . one of the treatment approaches of this disease include smoothing and polishing the rough surface and removing threads on the implants using rotary instruments, which is called implantoplasy. clinicians should perform implantoplasty with caution because it may raise th...

متن کامل

study of cohesive devices in the textbook of english for the students of apsychology by rastegarpour

this study investigates the cohesive devices used in the textbook of english for the students of psychology. the research questions and hypotheses in the present study are based on what frequency and distribution of grammatical and lexical cohesive devices are. then, to answer the questions all grammatical and lexical cohesive devices in reading comprehension passages from 6 units of 21units th...

development and implementation of an optimized control strategy for induction machine in an electric vehicle

in the area of automotive engineering there is a tendency to more electrification of power train. in this work control of an induction machine for the application of electric vehicle is investigated. through the changing operating point of the machine, adapting the rotor magnetization current seems to be useful to increase the machines efficiency. in the literature there are many approaches wh...

15 صفحه اول

the study of bright and surface discrete cavity solitons dynamics in saturable nonlinear media

امروزه سالیتون ها بعنوان امواج جایگزیده ای که تحت شرایط خاص بدون تغییر شکل در محیط منتشر می-شوند، زمینه مطالعات گسترده ای در حوزه اپتیک غیرخطی هستند. در این راستا توجه به پدیده پراش گسسته، که بعنوان عامل پهن شدگی باریکه نوری در آرایه ای از موجبرهای جفت شده، ظاهر می گردد، ضروری است، زیرا سالیتون های گسسته از خنثی شدن پراش گسسته در این سیستم ها بوسیله عوامل غیرخطی بوجود می آیند. گسستگی سیستم عامل...

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 31  شماره None

صفحات  191- 202

تاریخ انتشار 2013-11

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

کلمات کلیدی برای این مقاله ارائه نشده است

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023