The Quality Control of Intensity Modulated Radiation Therapy (IMRT) for ONCOR Siemens Linear Accelerators Using Film Dosimetry

نویسندگان

  • Alireza Amouheidari Radiation Oncologist, Department of Radiation-Oncology, Isfahan Milad Hospital, Isfahan, Iran
  • Keyvan Jabbari Department of Medical Physics and Engineering, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran
  • Shadi Babazadeh Radiation Oncologist, Department of Radiation-Oncology, Isfahan Milad Hospital, Isfahan, Iran
چکیده مقاله:

Introduction Intensity Modulated Radiation Therapy (IMRT) has made a significant progress in radiation therapy centers in recent years. In this method, each radiation beam is divided into many subfields that create a field with a modulated intensity. Considering the complexity of this method, the quality control for IMRT is a topic of interest for researchers. This article is about the various steps of planning and quality control of Siemens linear accelerators for IMRT, using film dosimetry. This article in addition to review of the techniques, discusses the details of experiments and possible sources of errors which are not mentioned in the protocols and other references. Materials and Methods This project was carried out in Isfahan Milad hospital which has two Siemens ONCOR linear accelerators. Both accelerators are equipped with Multi-Leaf Collimators (MLC) which enables us to perform IMRT delivery in the step-and-shoot method. The quality control consists of various experiments related to the sections of radiation therapy. In these experiments, the accuracy of some components such as treatment planning system, imaging device (CT), MLC, control system of accelerator, and stability of the output are evaluated. The dose verification is performed using film dosimetry method. The films were KODAK-EDR2, which were calibrated before the experiments. One of the important steps is the comparison of the calculated dose with planning system and the measured dose in experiments. Results The results of the experiments in various steps have been acceptable according to the standard protocols. The calibration of MLC and evaluation of the leakage through the leaves of MLC was performed by using the film dosimetry and visual check. In comparison with calculated and measured dose, more that 80% of the points have to be in agreement within 3% of the value. In our experiments, between 85 and 90% of the points had such an agreement with IMRT delivery. Conclusion The EDR2 films are suitable for quality control of IMRT. According to complexity of the quality control for IMRT, the physicists of each center have to develop specific guidelines according to their equipments and limitations. An accurate treatment planning system with capability of inverse planning is an essential need for IMRT. The result of the planning system has to be compared with experiments in various situations.   

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

the quality control of intensity modulated radiation therapy (imrt) for oncor siemens linear accelerators using film dosimetry

introduction intensity modulated radiation therapy (imrt) has made a significant progress in radiation therapy centers in recent years. in this method, each radiation beam is divided into many subfields that create a field with a modulated intensity. considering the complexity of this method, the quality control for imrt is a topic of interest for researchers. this article is about the various ...

متن کامل

Intensity modulated radiation therapy (IMRT) technique for left breast cancer by different numbers of beam fields

Background: Intensity Modulated Radiotherapy (IMRT) can improve radiotherapy (RT) results by improving healthy tissue sparing. Additionally, IMRT provides more consistent dose deliveries and suppresses secondary tumor formation. RT is a principal treatment in breast cancer (BC). Aim: To evaluate the outcome of the Radiotherapy Plans (RTP) that use IMRT technique to left breast and other organs,...

متن کامل

Intensity Modulated Radiation Therapy (IMRT) of the Breast and Lung

When Policy Topic is covered Intensity-modulated radiation therapy (IMRT) may be considered medically necessary as a technique to deliver whole breast irradiation in patients receiving treatment for left-sided breast cancer after breast-conserving surgery when all the following conditions have been met:  Significant cardiac radiation exposure cannot be avoided using alternative radiation techn...

متن کامل

Acr Practice Guideline for Intensity-modulated Radiation Therapy (imrt)

These guidelines are an educational tool designed to assist practitioners in providing appropriate radiologic care for patients. They are not inflexible rules or requirements of practice and are not intended, nor should they be used, to establish a legal standard of care. For these reasons and those set forth below, the American College of Radiology cautions against the use of these guidelines ...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 9  شماره 2

صفحات  111- 125

تاریخ انتشار 2012-06-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023