The Impact of Residual Geometric Inaccuracies on Normal Organ Doses in Image Guided-Radiation Therapy of Prostate Cancer Using On-Board Kilovoltage Cone-Beam Computed Tomography

نویسندگان

  • Dogukan Akcay 2. Radiation therapy department, Dokuz Eylul university hospital, Izmir, Turkey
  • Ismail volkan Tekcan 3. Medical Physics department, Institute of health sciences, Dokuz Eylul University, Izmir, Turkey
چکیده مقاله:

Introduction: The aim of this retrospective study was to evaluate the variations in delivered dose to the bladder, rectum, and femoral heads of prostate cancer patients during a course of treatment by image-guided radiation therapy (IGRT). Materials and Methods: Overall, 15 patients with prostate cancer were selected and. Each week, for each patient five consecutive cone beam computed tomography (CBCT) images were taken after bony anatomy alignment by using two orthogonal radiographic images, as well as CBCT images. Dose distributions and dose volume histograms (DVH) for all the original and CBCT plans were obtained. Maximum, as well as mean doses and volumes of the bladder, rectum, and both femoral heads were recorded for each CBCT plan and compared with the original CT plan. For all the studied body parts, the differences in DVH between CBCT plans and original CT plan were calculated and compared.          Results: Considering all the 75 CBCT images for the 15 patients, average of changes in mean doses and volumes were 17.8%, 41.8%, 7.1%, and 36.8% for the bladder and rectum, respectively. There was a significant (P

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cone-Beam Computed Tomography for Image-Guided Radiation Therapy of Prostate Cancer

Imaging plays a vital role in radiation therapy and with recent advances in technology considerable emphasis has been placed on cone-beam CT (CBCT). Attaching a kV x-ray source and flat panel detector directly to the linear accelerator gantry has enabled progress in target localization techniques, which can include daily CBCT set-up scans for some treatments. However, with an increasing number ...

متن کامل

the impact of using inspirational quotes on abstract vocabulary recall

the present study is an attempt to investigate the potential impact of inspirational quotes on improving english abstract vocabulary recall. to achieve this goal, a multiple choice language proficiency test of 60 items including vocabulary and grammar component was administered to a sample of 63 second-semester male and female students whose age ranged between 17 to 22 and they were studying en...

15 صفحه اول

the impact of e-readiness on ec success in public sector in iran the impact of e-readiness on ec success in public sector in iran

acknowledge the importance of e-commerce to their countries and to survival of their businesses and in creating and encouraging an atmosphere for the wide adoption and success of e-commerce in the long term. the investment for implementing e-commerce in the public sector is one of the areas which is focused in government‘s action plan for cross-disciplinary it development and e-readiness in go...

Applications of linac-mounted kilovoltage Cone-beam Computed Tomography in modern radiation therapy: A review

The use of Cone-beam Computed Tomography (CBCT) in radiotherapy is increasing due to the widespread implementation of kilovoltage systems on the currently available linear accelerators. Cone beam CT acts as an effective Image-Guided Radiotherapy (IGRT) tool for the verification of patient position. It also opens up the possibility of real-time re-optimization of treatment plans for Adaptive Rad...

متن کامل

Patient dose from kilovoltage cone beam computed tomography imaging in radiation therapy.

Kilovoltage cone-beam computerized tomography (kV-CBCT) systems integrated into the gantry of linear accelerators can be used to acquire high-resolution volumetric images of the patient in the treatment position. Using on-line software and hardware, patient position can be determined accurately with a high degree of precision and, subsequently, set-up parameters can be adjusted to deliver the i...

متن کامل

Prevalence of Idiopathic Osteosclerosis on Cone Beam Computed Tomography Images

Objectives: This study was performed to investigate the prevalence of idiopathic osteosclerosis on cone beam computed tomography (CBCT) images of patients. Methods: In this descriptive, cross-sectional study, 240 CBCT scans of patients (125 women, 115 men) referred to a private oral and maxillofacial radiology clinic in Tehran in 2013 were selected and evaluated. Presence of idiopathic osteosc...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 14  شماره 2

صفحات  104- 113

تاریخ انتشار 2017-06-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023