The Electrochemical Sensor for Selective Solid Phase Extraction of Pseudoephedrine Hydrochloride in a Real Sample
نویسندگان
چکیده مقاله:
In the current study, a new technique was developed for quantification and qualification of pseudoephedrine hydrochloride (PSE) in a real sample, which was based on electrochemical sensors and molecular imprinted polymer (MIP). The carbon paste electrode (CPE) was modified and optimized by a different ratio of MIP. MIP/CPE was used as the extraction and working electrode. Differential pulse voltammetry (DPV) method was utilized for measurement. The MIP (molecularly imprinted polymer) and NIP (non-imprinted polymer) were synthesized by various ratios of functional monomer (methacrylic acid) and cross-linker (ethylene glycol dimethacrylate) and template (pseudoephedrine hydrochloride). Some parameters such as pH, extraction time, MIP/CP ratio, stirring rate, and concentration of sample were optimized, and under these conditions, the oxidation peak current was proportional to the pseudoephedrine hydrochloride concentration over a range of 10-500 µM with the coefficient of determination 0.992 (R2). The limit of detection (LOD) was found about 0.274 µM and the limit of quantification (LOQ) was located about 0.825 µM. The relative standard deviation (RSD) was about 1.17%. The results indicated that the modified electrode had a specific ability in selective extraction of pseudoephedrine hydrochloride.
منابع مشابه
N-octyl-modified magnetite NPs for optimization of solid phase extraction for trace analysis of phenytoin in real samples
objective: Phenytoin is an anti-seizure medication used to treat epilepsy, as well as to control arrhythmias (irregular heartbeat) and to treat migraine headaches and nerve pain. It is recommended to determine the amount of this drug in the blood to control the seizure and prevent its toxicity. In the present study, a sensitive and simple procedure based on the dispersive solid phase extraction...
متن کاملFabrication of a Selective and Sensitive Electrochemical Sensor Modified with Magnetic Molecularly Imprinted Polymer for Amoxicillin
A modified electrochemical sensor for the determination of amoxicillin (AMX) was reported in this paper. The magnetic molecularly imprinted polymer (MMIP) were suspended in AMX solution and then collected on the surface of a magnetic carbon paste electrode (CPE) via a permanent magnet, situated within the carbon paste electrode and then the voltammetry signals were recorded. It was confirmed th...
متن کاملA Sensitive Electrochemical Sensor for Determination of Imipramine in Urine Sample Using Carbon Ionic Liquid Electrode Modified With Montomorillonite Nanoclay
We used an effective electrochemical sensor for the determination of imipramine at pH 7.2 using a carbon nanocomposite electrode. The electrode has been designed by incorporation of montmorillonite nanoclay into the carbon ionic liquid electrode. The high sensitivity of 1.714 μA (μM)-1, two linear calibration ranges of 0.1–2 μM and 2-40 μM, and detection limit of 19 nM were achieved. The relati...
متن کاملstudy of cohesive devices in the textbook of english for the students of apsychology by rastegarpour
this study investigates the cohesive devices used in the textbook of english for the students of psychology. the research questions and hypotheses in the present study are based on what frequency and distribution of grammatical and lexical cohesive devices are. then, to answer the questions all grammatical and lexical cohesive devices in reading comprehension passages from 6 units of 21units th...
The Spectrophotometric Determination of Nystatin in Real Samples Using Solid Phase Extraction Based on Sodium Dodecyl Sulphate-Coated Magnetite Nanoparticles
The purpose of this study was to separate and determine Nystatin in water, urine and plasma samples using a method based on sodium dodecyl sulfate (SDS) coated magnetic nanoparticles (nano-magnets Fe3O4) along with spectrophotometry which has been developed for to this end. Due to their excellent adsorption capacity and high chemical stability, nanoparticles can be modified by surfactants. The ...
متن کاملTemperature-responsive Solid-phase Extraction Column for Biological Sample Pretreatment.
We have developed a novel solid-phase extraction (SPE) system utilizing a temperature-responsive polymer hydrogel-modified stationary phase. Aminopropyl silica beads (average diameter, 40 - 64 μm) were coated with poly(N-isopropylacrylamide) (PNIPAAm)-based thermo-responsive hydrogels. Butyl methacrylate (BMA) and N,N-dimethylaminopropyl acrylamide (DMAPAAm) were used as the hydrophobic and cat...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 15 شماره 1
صفحات 8- 23
تاریخ انتشار 2021-01-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023