The Efficiency of Respiratory-gated 18F-FDG PET/CT in Lung Adenocarcinoma: Amplitude-gating Versus Phase-gating Methods

نویسندگان

  • Hiroshi Honda Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
  • Kazuhiko Himuro Division of Radiology, Department of Medical Technology, Kyushu University Hospital, Fukuoka, Japan
  • Masayuki Sasaki Department of Health Sciences, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
  • Satoshi Kawanami Department of Molecular Imaging and Diagnosis, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
  • Shingo Baba Department of Clinical Radiology, Kyushu University Hospital, Fukuoka, Japan
  • Takuro Isoda Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
  • Yasuhiro Maruoka Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
چکیده مقاله:

Objective(s): In positron emission tomography (PET) studies, thoracic movement under free-breathing conditions is a cause of image degradation. Respiratory gating (RG) is commonly used to solve this problem. Two different methods, i.e., phase-gating (PG) and amplitude-gating (AG) PET, are available for respiratory gating. It is important to know the strengths and weaknesses of both methods when selecting an RG methodfor a given patient. We conducted this study to clarify whether AG or PG is preferable for measuring fluorodeoxyglucose (FDG) accumulation in lung adenocarcinoma and to investigate patient conditions which are most suitable for AG and PG methods.Methods: A total of 31 patients (11 males, 20 females; average age: 11.6±70.1 yrs) with 44 lung lesions, diagnosed as lung adenocarcinoma between April 2012 and March 2013, were investigated. Whole-body FDG-PET/CT scan was performed with both PG and AG methods in all patients. The maximum standardized uptake value (SUVmax) of PG, AG, and the control data of these two methods were measured, and the increase ratio (IR), calculated as IR(%)= (Post – Pre)/Pre × 100, was calculated. The diameter and positionof lung lesions were also analyzed. We defined an ‘effective lesion’ of PG (or AG) as a lesion which showed a higher IR compared to AG (or PG). 8 (25.8%)Results: The average SUVmax and average IR were 7.94±8.99 and 25.6±21.4% in PG and 6.70±7.60 and 14.4±4.0% in AG, respectively. Although there was no significant difference between the average SUVmax of PG and AG (P=0.09), the average IR of PG was significantly higher than that of AG (P

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

the efficiency of respiratory-gated 18f-fdg pet/ct in lung adenocarcinoma: amplitude-gating versus phase-gating methods

objective(s): in positron emission tomography (pet) studies, thoracic movement under free-breathing conditions is a cause of image degradation. respiratory gating (rg) is commonly used to solve this problem. two different methods, i.e., phase-gating (pg) and amplitude-gating (ag) pet, are available for respiratory gating. it is important to know the strengths and weaknesses of both methods when...

متن کامل

Effect of respiratory gating on quantifying PET images of lung cancer.

UNLABELLED We have developed a new technique to gate lung 18F-FDG PET images in synchronization with the respiratory motion to reduce smearing due to breathing and improve quantitation of 18F-FDG uptake in lung lesions. METHODS A camera-based respiratory gating system, the real-time position management (RPM), is used to monitor the respiratory cycle. The RPM provides a trigger to the PET scan...

متن کامل

Amplitude gating for a coached breathing approach in respiratory gated 10 MV flattening filter‐free VMAT delivery

The purpose of this study was to investigate amplitude gating combined with a coached breathing strategy for 10 MV flattening filter-free (FFF) volumetric-modulated arc therapy (VMAT) on the Varian TrueBeam linac. Ten patient plans for VMAT SABR liver were created using the Eclipse treatment planning system (TPS). The verification plans were then transferred to a CT-scanned Quasar phantom and d...

متن کامل

The Impact of Optimal Respiratory Gating and Image Noise on Evaluation of Intratumor Heterogeneity on 18F-FDG PET Imaging of Lung Cancer.

Accurate measurement of intratumor heterogeneity using parameters of texture on PET images is essential for precise characterization of cancer lesions. In this study, we investigated the influence of respiratory motion and varying noise levels on quantification of textural parameters in patients with lung cancer. METHODS We used an optimal-respiratory-gating algorithm on the list-mode data of...

متن کامل

Triage of Limited Versus Extensive Disease on 18F-FDG PET/CT Scan in Small Cell lung Cancer

Objective(s): Small cell lung cancer (SCLC) is an aggressive neuroendocrine carcinoma, which accounts for 10-15% of pulmonary cancers and exhibits early metastatic spread. This study aimed to determine the added value of 18F-FDG PET/CT imaging in tumor, node, and metastasis (TNM) staging of SCLC, compared to the conventional computed tomography (CT) scan and its potential role as a prognosticat...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 5  شماره 1

صفحات  30- 36

تاریخ انتشار 2017-01-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023