The Effect of Scattering from Leg Region on Organ Doses in Prostate Brachytherapy for 103Pd, 125I and 131Cs Seeds
نویسندگان
چکیده مقاله:
Introduction Dose calculation of tumor and surrounding tissues is essential during prostate brachytherapy. Three radioisotopes, namely, 125I, 103Pd, and 131Cs, are extensively used in this method. In this study, we aimed to calculate the received doses by the prostate and critical organs using the aforementioned radioactive seeds and to investigate the effect of scattering contribution for the legs on dose calculations. Materials and Methods The doses to organs of interest were calculated using MCNPX code and ORNL (Oak Ridge National Laboratory) phantom. Results Doses to the prostate as a source of radiation for 125I, 103Pd, and 131Cs were approximately 108.9, 97.7, and 81.5 Gy, respectively. Bladder, sigmoid colon, and testes received higher doses than other organs due to proximity to the prostate. Differences between the doses when tallying with the legs intact and with the legs voided were significant for testes, sigmoid colon contents, and sigmoid colon wall because of their proximity to the prostate. There was also a good consistency between our results and the data published by Montefiore Medical Center and Albert Einstein College of Medicine for the prostate. Conclusion Scattering from leg region had a significant effect on doses to testes, sigmoid colon contents, and sigmoid colon wall in the pelvic region, and prostate and the other organs were unaffected. Brachytherapy treatment plans using 131Cs seeds allow for better sparing of critical tissues, with a comparable number of, or fewer, seeds required, compared to 125I seeds.
منابع مشابه
the effect of scattering from leg region on organ doses in prostate brachytherapy for 103pd, 125i and 131cs seeds
introduction dose calculation of tumor and surrounding tissues is essential during prostate brachytherapy. three radioisotopes, namely, 125i, 103pd, and 131cs, are extensively used in this method. in this study, we aimed to calculate the received doses by the prostate and critical organs using the aforementioned radioactive seeds and to investigate the effect of scattering contribution for the ...
متن کاملThe Effect of Scattering from Leg Region on Organ Doses in Prostate
Introduction Dose calculation of tumor and surrounding tissues is essential during prostate brachytherapy. Three radioisotopes, namely, 125 I, 103 Pd, and 131 Cs, are extensively used in this method. In this study, we aimed to calculate the received doses by the prostate and critical organs using the aforementioned radioactive seeds and to investigate the effect of scattering contribution for t...
متن کاملModification of Source Strength in Low-Dose-Rate Lung Brachytherapy with 125I and 103Pd seeds
Background:Â A new treatment approach for most patients who have undergone early stage non-small-cell lung carcinoma (NSCLC), is wedge resection plus permanent implant brachytherapy. However, the specification of dose to medium at low energies especially in heterogeneous lung is unclear yet.Objective:Â The present study aims to modify source strength for different configurations of 125I and 103...
متن کاملModification of Source Strength in Low-Dose-Rate Lung Brachytherapy with 125I and 103Pd Seeds
BACKGROUND A new treatment approach for most patients who have undergone early stage non-small-cell lung carcinoma (NSCLC) is wedge resection plus permanent implant brachytherapy. However, the specification of dose to medium at low energies especially in heterogeneous lung is unclear yet. OBJECTIVE The present study aims to modify source strength for different configurations of 125I and 103Pd...
متن کاملErratum: New National Air-Kerma-Strength Standards for 125I and 103Pd Brachytherapy Seeds
[This corrects the article on p. 337 in vol. 108.].
متن کاملNew National Air-Kerma-Strength Standards for 125I and 103Pd Brachytherapy Seeds
The new U.S. measurement standard for the air-kerma strength from low-energy photon-emitting brachytherapy seed sources is formally described in detail. This instrument-based standard was implemented on 1 January 1999, with its salient features and the implications of differences with the previous standard given only through a series of informal communications. The Wide-Angle Free-Air Chamber (...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 13 شماره 3
صفحات 203- 210
تاریخ انتشار 2016-09-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
کلمات کلیدی
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023