The dosimetry assessment of Varian Linear Accelerators of 6, 15 and 20 MV by Monte Carlo Method
نویسندگان
چکیده مقاله:
Introduction: Monte Carlo method is often applied in radiation therapy as utilized in all the branches of science. An important requirement for successful radiotherapy is carefully examine the dose distribution specifications and decrease the difference between these features with experience to an acceptable level. In this study, the characteristics of 6, 15 and 20 MeV incident x-rays are provided for 10×10 cm2 fields. This information is necessary to achieve an accurate treatment planning. Materials and Methods: The MCNP code is employed to simulate 6 MeV photon beam from a major manufacturer of a Varian linac accelerator. The used phantom in this research was water. The output data charts have illustrated, by two software origin and table curve. Results: In order to validate the performance and accuracy of the simulated head, the parameters associated with 5×5 cm2 field were compared to empirical values. In this study, 6, 15, 20 MeV (6, 15, 20 photon modes) energy spectra, percentage depth dose, beam profile are calculated. The comparisons between calculated and experimental results show good agreement (with ±4%). Conclusion: The MCNP code has a suitable precision in calculation of dose distribution for these modes of Varian. There is a good agreement between empirical and simulation result for 6 MV photon beam for both percentage depth dose and beam profiles. For the next two modes, comparing results with references indicates that the results are acceptable as well as other applications in radiotherapy.
منابع مشابه
Monte carlo simulation of varian clinac iX 10 MV photon beam for small field dosimetry
Background: The lack of lateral electronic disequilibrium (LED) becomes a main problem in small field. This factor affects the dose in target volume cannot predict correctly. In addition, utilization of high-energy linear accelerator (10 MV) can emit some unwanted particles (electron contamination). Therefore, the aim of this study was to characterize head linear accelerator (linac) Varian Clin...
متن کاملMonte Carlo modeling of a Novalis TX Varian 6 MV with HD‐120 multileaf collimator
A Monte Carlo model of the Novalis Tx linear accelerator equipped with high-definition multileaf collimator (HD-120 HD-MLC) was commissioned using ionization chamber measurements in water. All measurements in water were performed using a liquid filled ionization chamber. Film measurements were made using EDR2 film in solid water. Open rectangular fields defined by the jaws or the HD-MLC were us...
متن کاملMonte Carlo Study of Fetal Dosimetry Parameters for 6 MV Photon Beam
Because of the adverse effects of ionizing radiation on fetuses, prior to radiotherapy of pregnant patients, fetal dose should be estimated. Fetal dose has been studied by several authors in different depths in phantoms with various abdomen thicknesses (ATs). In this study, the effect of maternal AT and depth in fetal dosimetry was investigated, using peripheral dose (PD) distribution evaluatio...
متن کاملmonte carlo study of fetal dosimetry parameters for 6 mv photon beam
background: because of the adverse effects of ionizing radiation on fetuses, prior to radiotherapy of pregnant patients, fetal dose should be estimated. fetal dose has been studied by several authors in different depths in phantoms with various abdomen thicknesses (at). in this study, the effect of maternal at and depth in fetal dosimetry was investigated, using peripheral dose (pd) distributio...
متن کاملAssessment of skyshine photon dose rates from 9 and 18 MV medical linear accelerators
Background: Skyshine describes the radiation scattered by the atmosphere above a LINAC facility to a point on the ground. The aim of this study was to measure the skyshine photon dose rates from two different (9 MV and 18 MV) medical linear accelerators. Materials and Methods: The photon beam was directed upward (180° gantry position), with a maximum photon field size (40 × 40 cm2) at the isoce...
متن کاملThe plastic tray effect on the spectrum of photoneutrons prudused by 18 MV medical linac using the Monte Carlo method
Introduction: One of the important problems of using high energy linacs is the production of photoneutrons. High energy medical linacs produce secondary neutrons. These phtoneutrons increase patient dose Materials and Methods: In this study, the effect of plastic trays on spectrum of photoneutrons produced by 18MV linac is investigated using the MCNP4C code...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 15 شماره Special Issue-12th. Iranian Congress of Medical Physics
صفحات 453- 453
تاریخ انتشار 2018-12-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023