Test-retest reliability and minimal detectable change for center of pressure measures of postural stability in elderly subjects
نویسندگان
چکیده مقاله:
Abstract Background: Postural instability has been identified as a potential precursor of falls in elderly subjects. Postural stability in quiet stance is commonly assessed with center of pressure (COP) measures. The purpose of this study was to determine testretest reliability and minimal detectable change (MDC) for the center of pressure (COP) measures in the elderly subjects. Methods: Eighteen healthy elderly people over the age of 60 years participated in this study. For each subject the COP was recorded during quiet upright stance on different levels of postural difficulty (eyes open versus eyes closed, firm surface versus foam surface) and lean condition (forward and backward). All measurements were done on two sessions with 7 days interval. These indices: mean velocity, standard deviation of amplitude, standard deviation of velocity, phase plane parameter and area (95% confidence ellipse). Intraclass correlation coefficient (ICC), standard error of measurement (SEM) and coefficient of variation (CV) were used to quantify testretest reliability. The MDC for each measure was calculated to quantify intervention effects. Results: In general, test-retest reliability of COP measures in the elder subjects was increased whenever postural difficulty of task increased in quiet standing. In standing conditions, mean velocity and phase plane parameter were the most sensitive and the most reliable measures. The lean range was the most sensitive and the most reliable measure, in the lean conditions. Conclusion: Center of pressure measures in the quiet standing especially in difficult postural conditions demonstrated high sensitivity in the older subjects. These results may be useful in quantification and assessment of balance performance and treatment efficacy.
منابع مشابه
test-retest reliability and minimal detectable change for center of pressure measures of postural stability in elderly subjects
abstract background: postural instability has been identified as a potential precursor of falls in elderly subjects. postural stability in quiet stance is commonly assessed with center of pressure (cop) measures. the purpose of this study was to determine testretest reliability and minimal detectable change (mdc) for the center of pressure (cop) measures in the elderly subjects. methods: ei...
متن کاملThe Test-Retest Reliability and Minimal Detectable Change of the Fugl-Meyer Assessment of the Upper Extremity and 9-Hole Pegboard Test in Individuals With Subacute Stroke
Purpose: The first step to manage motor impairment of upper limb in patients with subacute stroke is having an accurate assessment tool. The Fugl-Meyer assessment of upper extremity and 9-hole pegboard test are used to evaluate motor function and hand dexterity in stroke survivals. The present study aimed to investigate the test-retest reliability and minimal detectable change (MDC) in these tw...
متن کاملTest-Retest Reliability of Dynamic Postural Stability Measures in Healthy and Chronic Non-specific Low Back Pain Groups
Objective: The primary aim of the present study was to study the reliability of postural stability measures during whole body dynamic conditions, so they can be used in postural stability evaluations, investigations of injury mechanisms and assessments of treatment efficacy. Materials & Methods: Twelve healthy volunteers and 12 low back pain patients performed repeated trunk bending motions ...
متن کاملTest-retest reliability of linear and nonlinear measures of postural stability during visual deprivation in healthy subjects
[Purpose] The purpose of this study is to evaluate the reliability of linear and nonlinear measures of the center of pressure (COP) during visual deprivation. [Subjects and Methods] Fifteen young adults participated in this study. COP signals were recorded in two conditions: eyes open and eyes closed. Three trials were performed in each condition with a rest period of approximately 1 min. The i...
متن کاملThe Test- Retest Reliability and Minimal Detectable Change of the Sensory Organization Test and Head- Shake Sensory Organization Test
متن کامل
the test-retest reliability and minimal detectable change of the fugl-meyer assessment of the upper extremity and 9-hole pegboard test in individuals with subacute stroke
purpose: the first step to manage motor impairment of upper limb in patients with subacute stroke is having an accurate assessment tool. the fugl-meyer assessment of upper extremity and 9-hole pegboard test are used to evaluate motor function and hand dexterity in stroke survivals. the present study aimed to investigate the test-retest reliability and minimal detectable change (mdc) in these tw...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 23 شماره 4
صفحات 224- 232
تاریخ انتشار 2010-02
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023