Sub-ppm determination of uric acid using a sensitive kinetic-catalytic reaction system

نویسندگان

  • A Sheibani Department of Chemistry, Yazd Branch, Islamic Azad University, Yazd, Iran
  • M Rezaie Department of Chemistry, Science and Research Branch, Islamic Azad University, Savah, Iran
چکیده مقاله:

A sensitive and selective kinetic-spectrophotometric method was developed for the determination of trace amounts of uric acid. The method is based on the inhibitory effect of uric acid on the oxidation of Janus Green by bromate in the presence of sulfuric acid. The reaction was followed spectrophotometrically by measuring the absorbance at 518 nm using the fixed-time method. Under optimum experimental conditions (Janus Green, 30.0 μmol L-1; sulfuric acid, 70.0 mmol L-1; bromate, 3.75 mmol L-1; 25 °C and 4.0 min), the calibration curve was linear over the range 0.3 - 46.1 μg mL-1 of uric acid and the detection limit was obtained 0.08 μg mL-1. The relative standard deviations (n=6) of 1.0 and 10.0 mg L-1 of uric acid were 1.14 and 1.08%, respectively. The influence of different foreign species that co-exist with uric acid was investigated in different matrices. The developed method was successfully applied for the determination of uric acid in biological samples.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

sub-ppm determination of uric acid using a sensitive kinetic-catalytic reaction system

a sensitive and selective kinetic-spectrophotometric method was developed for the determination of trace amounts of uric acid. the method is based on the inhibitory effect of uric acid on the oxidation of janus green by bromate in the presence of sulfuric acid. the reaction was followed spectrophotometrically by measuring the absorbance at 518 nm using the fixed-time method. under optimum exper...

متن کامل

Trace Amounts Determination of Vanadium (V) Using a New Kinetic-Catalytic Reaction System

This study describes a new simple, sensitive and selective catalytic kinetic spectrophotometricmethod for the determination of vanadium (V). The method is based upon the catalytic effect ofvanadium (V) on the oxidation of Carminic acid by bromate in sulfuric acid media. The reaction wasfollowed spectrophotometrically by measuring the decrease in absorbance at 490 nm and thedependence of sensiti...

متن کامل

trace amounts determination of vanadium (v) using a new kinetic-catalytic reaction system

this study describes a new simple, sensitive and selective catalytic kinetic spectrophotometricmethod for the determination of vanadium (v). the method is based upon the catalytic effect ofvanadium (v) on the oxidation of carminic acid by bromate in sulfuric acid media. the reaction wasfollowed spectrophotometrically by measuring the decrease in absorbance at 490 nm and thedependence of sensiti...

متن کامل

Catalytic Kinetic Determination of Silver through its Catalytic Effect on Congo Red-Peroxodisulphate Reaction

A kinetic-spectrophotometric procedure is reported for determination of trace amounts of Ag(I). This method is based on catalytic effect of silver ion on the oxidation of congo red by potassium peroxodisulphate at pH=3.4 and 30 oC in the presence of 1,10-phenanthroline as an activator. The reaction was followed spectrophotometrically by measuring the rate of change in absorbance ...

متن کامل

Application of Thionine Dye for Highly Sensitive and Selective Catalytic kinetic Determination of Osmium

Anew, highly sensitive and selective catalytic kinetic method (CKM) for determination of osmium (VIII) has been established based on its catalytic effect on the oxidation of thionine dye by hydrogen peroxide in alkaline medium. The reaction has been followed spectrophotometrically by measuring the decrease in the absorbance band of thionine at 600 nm. Under the optimum conditions, the proposed ...

متن کامل

A Highly Sensitive Kinetic Spectrophotometric Method for the Determination of Ascorbic Acid in Pharmaceutical Samples

In this study, a new reaction system for quantitative determination of ascorbic acid was introduced. The developed method is based on inhibitory effect of ascorbic acid on the Orange G-bromate system. The change in absorbance was followed spectrophotometrically at 478 nm. The dependence of sensitivity on the reaction variables including reagents concentration, temperature and time was investiga...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 2  شماره 1

صفحات  65- 75

تاریخ انتشار 2013-10-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023