Study of the Compton scattering effect of soft tissue in PET imaging by Monte Carlo method

نویسندگان

  • Araste, Narges Kharazmi International Campus - ShahroodUniversity of Technology
چکیده مقاله:

Introduction:In PET imaging, one or both of two annihilation photons may change the direction before reaching the detector due to Compton scattering interaction in body. .Methods:This article, a Monte Carlo simulation study, examined the effect of soft tissue on this error.In this work, the PET BiographTM 6 scanner, a simple geometry of soft tissue -including a sphere of soft tissue in center of PET ringwith various radii (from 0.5 to 30cm)- and two kinds of 511keV gamma source –point source and spherical source - were simulated by Monte Carlo MCNPX code to investigate scattering effect of soft tissue on PET imaging. Results:Analysis of the results of the simulation showed that, the majority scattered photons fell within the energy window without much loss of energy. Soft tissue around the point source at a distance of 8 to 12cm from the source and soft tissue around the spherical source at a distance of 8cm from the center had the most scattering effect in PET imaging. The scattering effect of soft tissue around the point source was more than the spherical source. Conclusion:The scattering effect of the adjacent organs is more than the non-adjacent organs.For high thicknessof soft tissue (more than20cm of radius), the attenuation effect is as obvious as the scattering effect. According to the results of this study, the patient's body thickness -in the abdominal region-could be a more accurate alternative for the patient's weight for increasing the injected dose into obese patients.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Monte Carlo Correction for the Effect of Compton Scattering in 3-d Pet Brain Imaging

A Monte Carlo simulation has been developed to simulate and correct for the effect of Compton scatter in 3-D acquired PET brain scans. The method utilizes the 3-D reconstructed image volume as the source intensity distribution for a photon-tracking Monte Carlo simulation. It is assumed that the number of events in each pixel of the image represents the isotope concentration at that location in ...

متن کامل

study of cohesive devices in the textbook of english for the students of apsychology by rastegarpour

this study investigates the cohesive devices used in the textbook of english for the students of psychology. the research questions and hypotheses in the present study are based on what frequency and distribution of grammatical and lexical cohesive devices are. then, to answer the questions all grammatical and lexical cohesive devices in reading comprehension passages from 6 units of 21units th...

A Monte Carlo Correction for Compton Scattering Effects in 3d Pet Brain Imaging

A Monte Carlo simulation has been developed to simulate and correct for Compton scattering effects in 3D acquired PET brain images. As input the routine requires the 3D reconstructed image volume of interest which is treated as a source intensity distribution for a photon-tracking Monte Carlo simulation. It is assumed that the number of counts in each pixel of the image represents the number of...

متن کامل

The study of neutron interactions with soft tissue using Monte Carlo simulation using the source PF

The most important part of neutron therapy treatment (NCT1) is to achieve a beam of neutrons with suitable energy and intensity, as well as the least pollution and damage. In this study, in order to correct the neutron spectrum from D-D fusion and its use in neutron therapy, a set of different materials which are called the Beam Shaping Assembly (BSA) was placed in the direction of energy 2.45 ...

متن کامل

The Influence of Crystal Size and Material on Intercrystal Scattering and Parallax in PET Block Detectors: A Monte Carlo Study

Introduction:  In  this  study,  we  utilized  the  MCNP4C  Monte  Carlo  code  to  quantitatively  evaluate  the  influence of crystal size and material on intercrystal scatter and parallax effects.   Materials and Methods:  For each of the 5 selected crystals (BGO, LSO, LYSO, LuAP, GSO), transport of  511  keV  photons  originating  from  a  point  source  and  incident  on  the  central  cry...

متن کامل

the effect of the record infancy in crimilly acts of guilties (in karaj city)

چکیده یکی از مهمترین دغدغه های بزرگ جوامع بشری، از دیر باز تا کنون که ذهن پژوهشگران و متخصصان بهداشت روانی و اجتماعی و دولتها رابه خود مشغول داشته، مسأله ی بزهکاری می باشد. شناخت کامل پدیده ی بزهکاری و بزهکار، علل وعوامل سقوط یک انسان، چگونگی درمان وی و درنهایت پیشگیری ازبزهکاری ودریک کلام سالم سازی یک جامعه، رسالت عظیم، انسانی ومقدسی می باشد که با بررسی شخصیت مجرم یعنی[ انسانی که تحت شرای...

15 صفحه اول

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 27  شماره 4

صفحات  1467- 1481

تاریخ انتشار 2019-08

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

کلمات کلیدی برای این مقاله ارائه نشده است

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023