Some steps towards establishing a tertiary standard dosimetry laboratory at a radiotherapy department

نویسندگان

  • A. Ebrahimzadeh Pezeshki Reza Radiotherapy Oncology Center, Mashhad, Iran
  • M. Mohammadi Department of Medical Physics, Hamadan University of Medical Science, Hamadan, Iran
  • S. Abdollahi Reza Radiotherapy Oncology Center, Mashhad, Iran
  • Z. Alizadeh Reza Radiotherapy Oncology Center, Mashhad, Iran
چکیده مقاله:

Background: In order to deliver the precise dose to the target in radiotherapy, absorbed dose to water at the reference point should be assessed. When the calibration procedure is performed for a reference dosimeter in the 60Co beam of a Secondary Standard Dosimetry Laboratory (SSDL), the total uncertainty in absorbed dose to water (Dw) is estimated to be approximately 1.5%. This study attempts to re-measure the ND,W factors for all available field chambers at Reza Radiotherapy & Oncology Centre (RROC). Materials and Methods: Consistency and linearity checks were performed for a range of available chambers using a check source. The ND,W factors were also measured for the ionization chambers. All cylindrical chambers have been cross calibrated at 6 MV photon beam using a Siemens Primus Plus Linac. The Plane Parallel Chamber has been cross calibrated at the highest available electron beam and the ND,W factor has been measured. Results: The tolerance of consistency and linearity checks has been reported to be within 0.3%. The ND,W value for field Farmer chamber was found in agreement with certificate within 1%. In contrast for small active volume chambers, the deviation from the SSDL reports was 2.3%. For the plane parallel chamber, the difference between SSDL and Home measurements are found to be 12%. Conclusion: Although the calibration of reference chambers used for absolute dosimetry through a Primary Standard Dosimetry Laboratory (PSDL) or SSDL is recommended, for field chambers this can be done at home department as a Tertiary Standard Dosimetry Laboratory (TSDL).

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

some steps towards establishing a tertiary standard dosimetry laboratory at a radiotherapy department

background: in order to deliver the precise dose to the target in radiotherapy, absorbed dose to water at the reference point should be assessed. when the calibration procedure is performed for a reference dosimeter in the 60co beam of a secondary standard dosimetry laboratory (ssdl), the total uncertainty in absorbed dose to water (dw) is estimated to be approximately 1.5%. this study attempts...

متن کامل

Assessment of Nuclear Moisture Density Gauges at a Secondary Standard Dosimetry Laboratory in Ghana during December 2015–December 2017

Introduction: Nuclear moisture density gauges are widely used in construction industry in different countries across the world, including Ghana, on a large scale. Like all irradiating devices, the nuclear gauges should be subjected to radiation safety assessment based on radiation protection and safety principles. Regarding this, the objective of this research was to i...

متن کامل

dosimetry of esophageal radiotherapy: a phantom study

esophageal cancer is the eighth most ordinary cancer and the sixth most common cancer between the males and ninth for females in the world; its major and effective treatment is external radiotherapy. this type of cancer can be found in different areas of esophagus including cervical, upper, middle and lower esophagus. in this treatment, healthy tissues such as the trachea, spine and sternum and...

متن کامل

Further Steps Towards a Standard Testbed for Optical Music Recognition

Evaluating Optical Music Recognition (OMR) is notoriously difficult and automated end-to-end OMR evaluation metrics are not available to guide development. In “Towards a Standard Testbed for Optical Music Recognition: Definitions, Metrics, and Page Images”, Byrd and Simonsen recently stress that a benchmarking standard is needed in the OMR community, both with regards to data and evaluation met...

متن کامل

Towards Establishing Capacity for Biological Dosimetry at Ghana Atomic Energy Commission

The aim of this study was not only to obtain basic technical prerequisites for the establishment of capacity of biological dosimetry at the Ghana Atomic Energy Commission (GAEC) but also to stimulate interest in biological dosimetry research in Ghana and Sub-Saharan Africa. Peripheral blood from four healthy donors was exposed to different doses (0-6 Gy) of gamma rays from a radiotherapy machin...

متن کامل

Some Steps Towards a Form of Parallel Distributed Genetic Programming

—Genetic Programming is a method of program discovery consisting of a special kind of genetic algorithm capable of operating on nonlinear chromosomes (parse trees) representing programs and an interpreter which can run the programs being optimised. This paper describes PDGP (Parallel Distributed Genetic Programming), a new form of genetic programming which is suitable for the development of fin...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 13  شماره None

صفحات  191- 196

تاریخ انتشار 2015-04

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023