Sentinel node detection failure due to defective labeling and large particle size of Tc-99m antimony sulfide colloid
نویسندگان
چکیده مقاله:
Introduction: Many radiotracers have been used for sentinel node mapping with acceptable results. The main difference between these radiotracers is the particle size. In the current study, we reported defective labeling of Tc-99m antimony sulfide colloid which resulted in large particle size. Methods: Tc-99m-Antimony sulfide colloid was used for axillary sentinel node mapping of 45 breast cancer patients. The prepared kits were turbid and were used for the first 15 patients. For the remaining 30 patients, we used a filter (GyroDisc CA-PC Cellulose Acetate Membrane; 30 mm; Pore size: 0.2 µm) after labeling to remove the possible large particles of the prepared kits. Results: On the lymphoscintigraphy images, at least one sentinel node could be identified in 5 and 29 patients of the unfiltered and filtered groups respectively (p=0.00001). Sentinel node detection by gamma probe was successful in 5 and 30 patients in the unfiltered and filtered groups respectively (p=0.000001). Conclusion: Tc-99-Antimopny sulfide colloid is a suitable radiotracer for sentinel node mapping of the breast cancer patients. In case of any unusual turbidity of the labeled kit, it should not be used or at least be filtered before injection.
منابع مشابه
sentinel node detection failure due to defective labeling and large particle size of tc-99m antimony sulfide colloid
introduction: many radiotracers have been used for sentinel node mapping with acceptable results. the main difference between these radiotracers is the particle size. in the current study, we reported defective labeling of tc-99m antimony sulfide colloid which resulted in large particle size. methods: tc-99m-antimony sulfide colloid was used for axillary sentinel node mapping of 45 breast cance...
متن کاملSentinel node detection failure due to defective labeling and large particle size of Tc - 99 m antimony sulfide colloid
Introduction: Many radiotracers have been used for sentinel node mapping with acceptable results. The main difference between these radiotracers is the particle size. In the current study, we reported defective labeling of Tc-99m antimony sulfide colloid which resulted in large particle size. Methods: Tc-99m-Antimony sulfide colloid was used for axillary sentinel node mapping of 45 breast cance...
متن کاملSentinel lymph node biopsy in melanoma patients: An experience with Tc-99m antimony sulfide colloid
Introduction: Sentinel lymph node biopsy is the standard procedure for lymph node staging in intermediate thickness melanoma. In Iran, this procedure has not been addressed sufficiently. In this study, we report our experience in this area. Methods: Ten consecutive patients with intermediate thickness melanoma where included in our study. 1.5 mCi of Tc-99m antimony...
متن کاملsentinel lymph node biopsy in melanoma patients: an experience with tc-99m antimony sulfide colloid
introduction: sentinel lymph node biopsy is the standard procedure for lymph node staging in intermediate thickness melanoma. in iran, this procedure has not been addressed sufficiently. in this study, we report our experience in this area. methods: ten consecutive patients with intermediate thickness melanoma where included in our study. 1.5 mci of tc-99m antimony sulfide colloid in two divide...
متن کاملThe efficacy of Tc-99m sestamibi for sentinel node mapping in breast carcinomas: comparison with Tc-99m antimony sulphide colloid.
BACKGROUND To study the value of periareolar intra-dermal injection of Tc-99m sestamibi (MIBI) for sentinel node mapping in breast carcinoma. MATERIAL AND METHODS Fifty patients with early-stage breast cancer were included in our study. 17.5 MBq Tc-99m-MIBI was injected intradermally to 25 patients and the remainders were injected with the same dose of Tc-99m-antimony sulphide colloid. Anteri...
متن کاملParticle size analysis of (99m)Tc-labeled and unlabeled antimony trisulfide and rhenium sulfide colloids intended for lymphoscintigraphic application.
UNLABELLED Colloidal particle size is an important characteristic to consider when choosing a radiopharmaceutical for mapping sentinel nodes in lymphoscintigraphy. METHODS Photon correlation spectroscopy (PCS) and transmission electron microscopy (TEM) were used to determine the particle size of antimony trisulfide and rhenium sulfide colloids, and membrane filtration (MF) was used to determi...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 19 شماره 1
صفحات 6- 11
تاریخ انتشار 2011-12-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023