Sensitivity of gallium scintigraphy for evaluation of recurrent lymphoma: Comparison of planar and SPECT imaging
نویسندگان
چکیده مقاله:
Introduction: Although PET scanning using F-18[FDG] is considered the superior radiotracer for tumnor imaging, Gallium-67 is still in use for some malignancies such as lymphoma and hepatoma. One of the strategies to improve the diagnostic accuracy of Gallium is to perform SPECT which is reported to be more sensitive compared to planar imaging. In this study we compared the sensitivity of SPECT and planar imaging in patients suspicious of thoracic recurrent lymphoma. Methods: 129 patients with suspicious recurrent lymphoma of the thorax were included into the study. All patients received 10 mCi Gallium-67-citrate intravenously. Twenty four and 48 hours post injection whole body and thoracic SPECT imaging was performed. The final diagnosis of recurrence was achieved by combination of clinical and imaging findings or pathologic examination whenever possible. Results: The final diagnosis of 83 (64.3%) patients was recurrence of lymphoma in the thoracic area and the remainder 46 (35.7%) were in remission. The sensitivity of planar and SPECT imaging for diagnosis of recurrent lymphoma was 63% ([52-73%] with 95% confidence intervals) and 87% ([79-94%] with 95% confidence intervals), respectively. Conclusion: In our study, 20 patients with the final diagnosis of lymphoma recurrence in the thoracic area had negative planar despite positive SPECT imaging. This showed an increase of 24% in sensitivity of the scan (from 63% to 87%) by adding SPECT imaging to the procedure. Our recommendation is integrating SPECT modality into all gallium scintigraphy for lymphoma recurrence.
منابع مشابه
sensitivity of gallium scintigraphy for evaluation of recurrent lymphoma: comparison of planar and spect imaging
introduction: although pet scanning using f-18[fdg] is considered the superior radiotracer for tumnor imaging, gallium-67 is still in use for some malignancies such as lymphoma and hepatoma. one of the strategies to improve the diagnostic accuracy of gallium is to perform spect which is reported to be more sensitive compared to planar imaging. in this study we compared the sensitivity of spect ...
متن کاملComparison between early and delayed images of 67Ga scintigraphy for evaluation of recurrent lymphoma
Introduction: Despite widespread use of 67Gallium for lymphoma evaluation, timing of imaging after injection is a matter of controversy and to the extent of our knowledge no direct comparison has been made between early and delayed gallium images. We aimed to compare 24 and 48 hours post injection planar gallium imaging for evaluation of lymphoma recurrence. Methods: 255 pa...
متن کاملcomparison of zoe and vitapex for canal treatment of necrotic primary teeth
چکیده ندارد.
15 صفحه اولthe evaluation and comparison of two esp textbooks available on the iranian market for teaching english to the students of medicine
abstract this study evaluated and compared medical terminology and english for the students of medicine (ii) as two representatives of the textbooks available on the iranian market for teaching english to the students of medicine. this research was performed on the basis of a teacher’s and a number of students’ attitudes and the students’ needs analysis for two reasons: first, to investigate...
15 صفحه اولa comparison of linguistic and pragmatic knowledge: a case of iranian learners of english
در این تحقیق دانش زبانشناسی و کاربردشناسی زبان آموزان ایرانی در سطح بالای متوسط مقایسه شد. 50 دانش آموز با سابقه آموزشی مشابه از شش آموزشگاه زبان مختلف در دو آزمون دانش زبانشناسی و آزمون دانش گفتار شناسی زبان انگلیسی شرکت کردند که سوالات هر دو تست توسط محقق تهیه شده بود. همچنین در این تحقیق کارایی کتابهای آموزشی زبان در فراهم آوردن درون داد کافی برای زبان آموزان ایرانی به عنوان هدف جانبی تحقیق ...
15 صفحه اولcomparison between early and delayed images of 67ga scintigraphy for evaluation of recurrent lymphoma
introduction: despite widespread use of 67gallium for lymphoma evaluation, timing of imaging after injection is a matter of controversy and to the extent of our knowledge no direct comparison has been made between early and delayed gallium images. we aimed to compare 24 and 48 hours post injection planar gallium imaging for evaluation of lymphoma recurrence. methods: 255 patients suspicious of...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 18 شماره 1
صفحات 45- 51
تاریخ انتشار 2010-01-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
کلمات کلیدی
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023