Selective Separation and Preconcentration of trace Amounts of Gallium in Water and Rice Samples using Cloud Point Extraction and Determination by Inductively Coupled Plasma-Atomic Emission Spectrometry

نویسندگان

  • Mina Roshdi Faculty of Chemistry, Kharazmi University, Tehran, Iran
چکیده مقاله:

In the present study a cloud-point extraction process using non-ionic surfactant Triton X-114 for selective extraction of gallium from aqueous solutions was developed. The method is based on the complex formation of Ga (III) with N, N′ -bis (salycilidene)-1, 2-phenylenediamine (salophen) as a chelating agent in buffer media of pH 5. After phase separation and dilution of the surfactant-rich phase with 0.2 mL of a (80-20) propanol-water mixture containing 0.02 mL HNO3, the enriched analyte was determined by inductively coupled plasma-atomic emission spectrometry (ICP-AES). The variables affecting the complexation and extraction steps were optimized. Under the optimum conditions (i.e. 7.5×10-5 mol L-1 salophen, 0.5% (v/v) Triton X-114, 45ºC equilibrium temperature, incubation time 15 min) the calibration graph was linear in the range of 20–120 ng mL-1 with detection limit of 1.5 ng mL-1. The precision (R.S.D. %) for five replicate determinations at 60 ng mL-1 of Ga (III) was better than 4%. In this manner, the preconcentration factor was 22.2. Under the presence of foreign ions, no significant interference was observed. Finally, the proposed method was utilized successfully for the determination of gallium in water and rice samples.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of lead and cadmium in water samples by cloud point extraction prior to flame atomic absorption spectrometry determination

Pb and Cd in water samples were determined by cloud point extraction (CPE) with sodiumdiethyldithiocarbamate (DDTC) as the chelating agent and octylphenoxypolyethanl (Triton X-114) asthe surfactant prior to flame atomic absorption spectrometry (FAAS) determination. The main factorsof affecting the extraction and detection processes were optimized. The preconcentration of 10 mL ofstandard soluti...

متن کامل

Separation, Preconcentration and determination of Hg (II) Ion in Water Samples by Cloud Point Extraction Technique Coupled with UV-VIS Spectrophotometry using a New Complexing Agent

 In this study a cloud-point extraction process using non-ionic surfactant Triton X-114 for extraction of mercury (II) from aqueous solutions was developed. The method is based on the complex formation of Hg (II) with benzyl (pyridin-2-yl) methylcarbamodithioate at pH 5.5. After preconcentration and dilution of the surfactant-rich phase, the enriched analyte was determined by s...

متن کامل

Determination of Trace Copper(II) in Food Samples by Flame Atomic Absorption Spectrometry after Cloud Point Extraction

A new method for the determination of trace copper(II) in food samples by Cloud Point Extraction(CPE) combined with Flame Atomic Absorption Spectrometry(FAAS) is presented and evaluated. The method is based on the fact that hydrophobic complex of copper(II) with sodium diethyldithiocarbamate (DDTC) was formed at pH 6.0 and subsequently the hydrophobic complex was extracted into surfactant-r...

متن کامل

Preconcentration and speciation of chromium in water samples by atomic absorption spectrometry after cloud-point extraction.

A rapid, sensitive and accurate atomic absorption method for Cr(III) and Cr(VI) ions was developed based on the cloud-point extraction (CPE) technique. Cr(III) reacts with a new Schiff's base ligand to form the hydrophobic complex, which is subsequently entrapped in the surfactant micelles. The Cr(VI) assay is based on its reduction to Cr(III) by the addition of concentrated H2SO4 and ethanol t...

متن کامل

Determination of Trace Amount of Zn2+ Ion in soil, blood and vegetable and water samples by Flame Atomic Absorption Spectrometry After Cloud Point Extraction Using Selective Synthesis Ligand2-(3- indolyl) – 4,5 di phynyl imidazole.

  Abstract A simple, sensitive and feasible cloud-point extraction (CPE) methodology has been developed for the separation and preconcentration of cadmium and lead ions in real samples. The metals in the aqueous solution were complexes with 2-(3- indolyl) - 4,5 di phynyl imidazole.(IDPI), at pH = 7.0 and Triton X-114 was added as surfactant. The variables effecting like concentration of Triton ...

متن کامل

Simultaneous Determination of Carbazoles in Water Samples by Cloud Point Extraction Coupled to HPLC

Cloud point extraction (CPE) as a rapid, simple and efficient method coupled with high performance liquid chromatography (HPLC) was used for sample preparation and subsequent determination of carbazole, trinitrocarbazole (TrNC) and tetra nitro carbazole (TNC) in water samples. Some effective parameters on extraction, such as volume of Triton X-100, extraction time, extraction temperature, ionic...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 5  شماره 3

صفحات  534- 549

تاریخ انتشار 2018-07-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023