Seismic Rehabilitation of Liquid Storage Tanks using Friction Pendulum Base Isolation subjected to the Near-Fault Ground Motions

نویسندگان

چکیده مقاله:

Cylindrical liquid storage tanks are considered as vital structures in industrial complex whose nonlinear dynamic behavior is of crucial importance. Some of these structures around the world have demonstrated poor seismic behavior over the last decades. There are several methods and techniques for rehabilitation and reducing damages in these structures which among them passive control devices, in particular seismic base isolators, are noticeable. Friction Pendulum System (FPS) is the most popular base isolation system. In this paper, the effectiveness of FPS is studied on reducing the seismic responses of base isolated liquid storage tanks as well as the impact effect of slider to the side restrainer. To this end, the whole mass of liquid storage tank is considered as three lumped masses known as convective mass, impulsive mass which is connected to tanks with corresponding spring, and rigid mass which is connected rigidly. By means of state space method the time history analysis is done using 60 earthquake records to obtain dynamic responses under the different hazard levels i.e. SLE, DBE and MCE ground motions. The results show that the normalized base shear force in squat tank decreased 59%, 62% and 33% respectively under SLE, DBE and MCE ground motions. The reduction of normalized base shear force in slender tank is 53%, 49% and 35% under the aforementioned hazard levels. Examining the effect of side restrainer’s stiffness on the maximum responses show that the impact effect must be considered particularly when the system is excited by MCE’s ground motions.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of Seismic Pounding on RC Buildings with and without Base Isolation System Subject to Near-Fault Ground Motions

Building pounding occurs between two adjacent buildings with small gap or without sufficient separation distance. It leads to damage buildings during earthquake due to impact. Many researchers have investigated building pounding based on impact force reduction and energy dissipation increase, when two buildings collide with each other. In numerical investigations, using specific link element, i...

متن کامل

Seismic Behavior of Jacket Offshore Platform Subjected to Near and Far Field Ground Motions

Offshore structures such as jacket platforms have to inevitably be designed against  sever  environmental actions. In seismically active areas these structures also become susceptible to earthquake excitations. Strong ground motions recorded  in recent earthquakes, including the 1995 Kobe, Japan, 1999 Chi-chi, Taiwan and 1999 Kocaeli, Turkey earthquakes, revealed that the dynamic motions in nea...

متن کامل

influence of seismic pounding on rc buildings with and without base isolation system subject to near-fault ground motions

building pounding occurs between two adjacent buildings with small gap or without sufficient separation distance. it leads to damage buildings during earthquake due to impact. many researchers have investigated building pounding based on impact force reduction and energy dissipation increase, when two buildings collide with each other. in numerical investigations, using specific link element, i...

متن کامل

Evaluation of Soil-Structure Interaction on the Seismic Response of Liquid Storage Tanks under Earthquake Ground Motions

Soil-structure interaction (SSI) could affect the seismic response of structures. Since liquid storage tanks are vital structures and must continue their operation under severe earthquakes, their seismic behavior should be studied. Accordingly, the seismic response of two types of steel liquid storage tanks (namely, broad and slender, with aspect ratios of height to radius equal to 0.6 and 1.85...

متن کامل

Evaluation of 2D concentrically braced frames with cylindrical dampers subjected to near-field earthquake ground motions

Near field earthquakes have imposed major damage to buildings in the past years. In some cases, the intensity of such damage is too considerable to be disregarded. The most effective way to improve seismic performance of buildings is applying a seismic control technique. The cylindrical friction damper is one of these methods, which has become popular for its desirable performance in the energy...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 7  شماره 1

صفحات  351- 365

تاریخ انتشار 2019-02-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023