Second Molar Uprighting with Temporary Anchorage Devices: A Finite Element Study

نویسندگان

  • H Majd Postgraduate Student of Orthodontics
چکیده مقاله:

BACKGROUND AND OBJECTIVE: Premature loss of mandibular first molar is a common problem in adults. Mesial tipping of second molar may occur in this situation. Various orthodontic mechanics have been proposed for molar uprighting. The aim of this study was to compare four methods of molar uprighting using Finite Element Analysis(FEM). METHODS: In first model of this finite element study, a 0.019×0.025 inch beta-titanium segmental arch wire with a T-loop was used. In second model a miniscrew was inserted in retromolar space and force was applied using elastomeric chain. The third model was a piece of 0.016×0.022inch beta-titanium wire with a bend which was placed more occlusal than the screw. The fourth model contained a mesially inserted miniscrew with an angle of 70 degrees to bone surface and a 0.018×0.025inch beta-titanium wire with helix. Extrusion, center of rotation and stress distribution in PDL during movement was compared between methods. FINDINGS: Buccal cusp extruded 1.36E-03, 1.13E-03, -9.74E-04 and 1.49E-03 mm in first, second, third and fourth model, respectively. Similarly, in lingual cusp, the amount of vertical displacement was at least in third model (-6.83E-04 mm). This amount in second and first method was 1.12E-03 and 4.05E-04 mm, respectively. The maximum amount of extrusion of lingual cusp occurred in fourth model (9.01E-03 mm). Mesial and distal cusps extruded 2.12E-04 and 1.58E-03 mm in first model, -1.14E-03 and 3.80E-03 mm in second method, -2.37E-03 and 7.04E-04 mm in third design and, 1.88E-03 and 8.57E-03 mm in the fourth model. The center of rotation was located at molar bifurcation in third model. CONCLUSION: The maximum amount of extrusion in both mesiodistal and buccolingual path was seen in fourth model. The best type of movement was found in third model, in which minimum extrusion occurred and center of rotation located at molar bifurcation.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mandibular molar protraction with temporary anchorage devices.

351 P of mandibular molars is challenging because of the high density of mandibular bone. Anterior dental anchorage is often inadequate to protract even a single first molar without reciprocal retraction of the incisors or movement of the dental midline. Furthermore, if the buccal and lingual cortical plates in the edentulous region have collapsed, safe and effective protraction may be impossib...

متن کامل

Preprosthetic molar uprighting using skeletal anchorage.

after extraction or loss of a first molar, the second molar may tip mesially into the edentulous space. Not only will the first-molar space contract mesiodistally, but eccentric occlusal loading will reduce the biomechanical loading capacity of the second molar. Such a situation requires preprosthetic up righting of the second molar using appropriate mechanics. Simply tipping the molar distally...

متن کامل

The use of temporary anchorage devices for molar intrusion.

BACKGROUND This article reviews the use of temporary anchorage devices (TADs) for maxillary molar intrusion. TYPES OF STUDIES REVIEWED The authors reviewed clinical, radiographic and histologic studies and case reports. The studies provided information regarding the application, placement and biological response of orthodontic TADs. RESULTS TAD-supported molar intrusion is controlled and ti...

متن کامل

Experience with orthodontic temporary anchorage devices

In orthodontics, anchorage is a prerequisite for the application of therapeutic forces and can limit their successful use. According to the intended treatment goals, desired tooth movements should, therefore, be maximized and undesirable effects minimized. But additional anchorage such as extraand intraoral forces are visible and hence compliance dependent and are associated with the risk of un...

متن کامل

Corrosion of orthodontic temporary anchorage devices.

Corrosion of orthodontic miniscrews or temporary anchorage devices (TADs) has been proposed as a contributor to inflammation, which in turn is a factor in the clinical success of miniscrews. The purpose of this study was to measure the electrochemical properties of orthodontic miniscrews in artificial saliva with and without fluoride. The corrosion properties of three miniscrew products (Vector...

متن کامل

T-Loop Position and Anchorage Control: A Finite Element Study

Objective: To determine the effect of T loop spring position and activation on moment to force ratio. Materials and methods: Study conducted in two parts: (1) By using loop software by Halazonetis. Parameters studied were later on evaluated using FEM. Material properties along with the cross-sectional parameters being the same as in FEM, (2) using FEM, a large deflection nonlinear static analys...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 20  شماره 11

صفحات  7- 12

تاریخ انتشار 2018-11

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023