Research Paper: Anthropometric Study of Hip Joint in Tehran Population Using Computed Tomography Scan

نویسندگان

  • Bahman Jalali Kondori Department of Anatomical Sciences, School of Medical Sciences, Baqiyatallah University of Medical Sciences, Tehran, Iran.
  • Hossein Bahadoran Department of Anatomical Sciences, School of Medical Sciences, Baqiyatallah University of Medical Sciences, Tehran, Iran.
  • Mohammad Hossein Asadi Department of Anatomical Sciences, School of Medical Sciences, Baqiyatallah University of Medical Sciences, Tehran, Iran.
  • Sonia Dadseresht Department of Anatomical Sciences, School of Medical Sciences, Baqiyatallah University of Medical Sciences, Tehran, Iran.
چکیده مقاله:

Introduction: Anthropometric studies provide valuable information in different populations. This study was conducted to evaluate the anatomical variations of the normal hip joint among Tehran population, Iran, in comparison with other populations. Methods: This study was carried out on hip joint of 260 patients in all ages and both genders referred to the Department of Radiology at Ebn-e Sina Hospital, Tehran, Iran between April 2014 to September 2015. The average age of the patients was 42 years. To perform the anthropometric calculations, a topogram scan and an axial view of the patient’s hip joint were taken using multi-slice CT scan device. Parameters of center edge angle, neck shaft angle, acetabular angle, and acetabular depth were measured in all patients. The patients with center edge angle less than 20 degrees were marked as dysplastic patients and excluded from the study. Results: The mean center edge angle of the patients was 32 degrees and their mean neck shaft angle was 139.5 degrees. In this study, the mean patients’ acetabular angle and depth was 37.1 degrees and 1.67 cm, respectively. The neck shaft angle in women was 2.5 degrees more than that in men. Other parameters showed no significant differences between men and women. Conclusion: Comparison of the present results with the findings of other studies indicates differences in some parameters among various populations. The mean neck shaft angle in our study was about 6 to 7 degrees more than that in other populations. The parameters of center edge angle, acetabular angle, and acetabular depth were approximately equal to the results of other studies.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Research Paper: A comparison of Prevalence of Dilaceration in Mandible and Maxilla Using Cone Beam Computed Tomography in an Iranian Population

Abstract Introduction: dilaceration is a disturbance in tooth formation that produces a sharp bend or curve in the tooth. this anomaly has a negative effect on the treatment of root canals, orthodontics and surgery. The aim of this study was to determine the prevalence of root dilaceration using Cone Beam Tomography (CBCT). Materials and Methods:In this study, a total of 206 CBCT images(5434t...

متن کامل

Estimation of diagnostic reference levels for children computed tomography: A study in Tehran, Iran

Background: The Diagnostic reference levels (DRLs) play a critical role in the optimization of radiation dose especially, in some conditions like pediatrics. They are useful indicators by which the radiologists can be aware of delivered excess radiation doses to the patients, and take corrective actions if necessary. In order to meet some requirements for establishing the national computed tomo...

متن کامل

Multiple chest nodules on computed tomography scan.

Digital Object Identifier: 10.1188/03.CJON.697-698 Mr. M is a 75-year-old man recently diagnosed with chronic lymphocytic leukemia. The first two courses of chemotherapy were administered without problems, and Mr. M said he was feeling well enough to continue the remodeling of his home. While undergoing his third course of chemotherapy, he returned to the outpatient clinic with neutropenia, fev...

متن کامل

Computed Tomography Scan and ICD Interaction

Although it has been considered a safe procedure, computed tomography scanning uses high doses of radiation and can cause malfunctioning in those patients with ICD when the radiation is directly incident on the device. We present a case of ventricular oversensing during a thoracic computed tomography.

متن کامل

Pulmonary embolism: lung scan and computed tomography.

The diagnosis of pulmonary embolism may be confounded by a clinical presentation that is often subtle or atypical. Therefore pulmonary angiography, although invasive, has been widely used to prove pulmonary embolism. The aim of this review is to discuss the value of non-invasive techniques, such as lung scan and chest computed tomography scan, in the diagnosis of pulmonary embolism. Ventilation...

متن کامل

Anatomic variations of sphenoid sinus from Cone Beam Computed Tomography images in the Iranian population

Aims: Sphenoid sinus is one of the most inaccessible paranasal sinus, and is closely correlated to many vascular and neural structures. Anatomic variation of the sphenoid sinus can complicate surgery in this area. The aim of the present investigation was to define the sphenoid sinus variations and the relevant structures using cone-beam computed tomography (CBCT). Methods: This cross-sectiona...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 13  شماره 4

صفحات  221- 224

تاریخ انتشار 2016-11

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com