Real Time Calibration of Strap-down Three-Axis-Magnetometer for Attitude Estimation
نویسنده
چکیده مقاله:
Three-axis-magnetometers (TAMs) are widely utilized as a key component of attitude determination subsystems and as such are considered the corner stone of navigation for low Earth orbiting (LEO) space systems. Precise geomagnetic-based navigation demands accurate calibration of the magnetometers. In this regard, a complete online calibration process of TAM is developed in the current research that considers the combined effects of environmental and instrumental errors including biases, non-orthogonally parameters ,and the scale factors, without the need for clean room facilities. The sensor characteristics are estimated utilizing Kalman filter for a micro electro-mechanical sensor(MEMS)-based TAM standing on the experimental measured outputs in a noisy laboratory environment. Moreover, the stochastic TAM behavior is identified using the method of Allan variance analysis (AVA) through a six-hour static test. Subsequently, the nonlinear/non-Gaussian problem of attitude estimation, using a set of calibrated strap-down magnetometers is addressed utilizing the unscented particle filter (UPF), developed for the removal of colored-noise. Comparison of the estimated attitude, represented by quaternion parameters, with the true orientations demonstrates an acceptable level of accuracy of the developed calibration technique for small LEO space systems. Analysis of the root mean square error of the estimated attitude illustrates an accuracy of less than one degree for all axes. This is an ideal result, given the fact that MEMS-based magnetometers have been utilized.
منابع مشابه
Comprehensive Calibration of Strap-Down Tri-Axis Accelerometer Unit
Xi Zhang 1,2, Jie Li 1,3,*, Li Qin 1,3 and Chong Shen 3,4 1 National Key Laboratory for Electronic Measurement Technology, North University of China, Taiyuan 030051, China; [email protected] (X.Z.); [email protected] (L.Q.) 2 School of Computer Science and Control Engineering, North University of China, Taiyuan 030051, China 3 School of Instrument and Electronics, North University of China, Tai...
متن کاملMagnetic Calibration of Three-Axis Strapdown Magnetometers for Applications in Mems Attitude-Heading Reference Systems
In a strapdown magnetic compass, heading angle is estimated using the Earth's magnetic field measured by Three-Axis Magnetometers (TAM). However, due to several inevitable errors in the magnetic system, such as sensitivity errors, non-orthogonal and misalignment errors, hard iron and soft iron errors, measurement noises and local magnetic fields, there are large error between the magnetometers'...
متن کاملNovel Calibration Algorithm for a Three-Axis Strapdown Magnetometer
A complete error calibration model with 12 independent parameters is established by analyzing the three-axis magnetometer error mechanism. The said model conforms to an ellipsoid restriction, the parameters of the ellipsoid equation are estimated, and the ellipsoid coefficient matrix is derived. However, the calibration matrix cannot be determined completely, as there are fewer ellipsoid parame...
متن کاملAttitude-Independent Magnetometer Calibration with Time-Varying Bias
We present a method for on-orbit, attitudeindependent magnetometer calibration that includes the effect of time-varying bias due to electronics on-board a spacecraft. The calibration estimates magnetometer scale factors, mis-alignments, and constant as well as time-varying bias. Timevarying effects are mitigated by including spacecraft telemetry in the measurement model and estimating constant ...
متن کاملLine of Sight (LOS) rate estimation in strap down seekers using discrete-time extended state observer.
The line of sight (LOS) rate is a parameter that is needed to calculate the acceleration applied to missiles by the proportional guidance laws in order to hit the target. This rate is usually measured using gimbaled seekers. However, if the type of missile seeker be strap down, the LOS rate must be calculated from deriving the missile's seeker output angles or estimation methodes. The derivatio...
متن کاملThree - Axis Fiber Laser Magnetometer
Introduction: Acoustic detection of targets in shallow water environments is difficult due to high levels of anisotropic acoustic background noise. Detection range can be improved by simultaneously measuring nonacoustic signatures such as electromagnetic fields. A fiber laser vector magnetometer has been developed for seabed-mounted surveillance arrays. Three orthogonally mounted sensors measur...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 10 شماره 2
صفحات -
تاریخ انتشار 2634-07-23
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023