Radiation Oncology Medical Physics Workload calculation: A Change in Current Workload

نویسندگان

  • Fatemeh Akbari Department of Medical Physics, Reza Radiotherapy and Oncology Center, Mashhad, Iran
  • Fatemeh Varshoee Tabrizi Department of Medical Physics, Reza Radiotherapy and Oncology Center, Mashhad, Iran
  • Leila Sobh-Khiz Sabet Department of Medical Physics, Reza Radiotherapy and Oncology Center, Mashhad, Iran
  • Mohammad Mohammadi Department of Medical Physics, Royal Adelaide Hospital, Adelaide, SA 5000 AUSTRALIA. School of Physical Sciences, the University of Adelaide, SA 5005 AUSTRALIA. Department of Medical Physics, Reza Radiotherapy and Oncology Center, Mashhad, Iran
  • Sara Abdollahi Department of Medical Physics, Reza Radiotherapy and Oncology Center, Mashhad, Iran
چکیده مقاله:

Introduction: It is an essential activity to quantify the Radiation Oncology Medical Physics (ROMP) workload for a safe, secure and progressive department. Due to the most recent development at Reza radiotherapy and Oncology Centre (RROC), a workload calculator tool is provided.   Materials and Methods: The Project was performed in different sections including acquiring information and system abilities and failures, data processing and analysis, recommending the results to the executive section and, receiving and analyzing the feedback from Radiation Oncology Medical Physicists (ROMPs) employed at RROC.   Results: Based on interview with ROMPs, who are engaged with professional tasks at planning, dosimetry, Brachytherapy, health Physics, commissioning a machine or radiotherapy technique, as well as amount of patients referred to RROC for radiotherapy, a workload for ROMPs was estimated. It has been found that for average of 225 new patients per month, 8.55 Full Time Equivalent (FTE) is required. For a commissioning and running advanced techniques, such as Intensity Modulated Radiotherapy (IMRT), the total FTE for ROMP contribution including, planning and Patient Specific Quality Assurance (PSQA) tasks was also found to be 1.74 FTE for every 10 new cases. The FTE for Brachytherapy tasks with average 78.5 cases per month including cylinder, tandem, tandem & ovoid, and esophagus cases, and linear accelerator maintenance the average FTE were found to be 2.49 and 2.34, respectively. The study shows relying the computer based managerial affairs is able to reduce the ROMP administrative tasks significantly.   Conclusion: A professional administrative study for ROMP section will be able to determine the real, secure and safe workload for the section. The workload of ROMPs strongly depends on the level of the treatment quality and it should be taken into account as a dedicated plan for each department.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Medical physics in Current Oncology

Medical physics can be generally defined as a field in which applied physics techniques are used in medicine. Traditionally, medical physics deals chiefly with the use of ionizing or non-ionizing radiation in the diagnosis and treatment of disease. In radiation therapy, ionizing radiation is used to treat a wide variety of cancers through external-beam radiotherapy or brachytherapy. Medical phy...

متن کامل

Radiation Oncology and Medical Physics

1Medical Physics & Informatics Laboratory of Electronics Engineering, National Kaohsiung University of Applied Sciences, Kaohsiung 80778, Taiwan 2Graduate Institute of Clinical Medicine, Kaohsiung Medical University, Kaohsiung 807, Taiwan 3Department of Radiation Oncology, Institute for Advanced Radiation Oncology, Monmouth Medical Center, Barnabas Health, Long Branch, NJ 07601, USA 4Department...

متن کامل

Impact of an electronic chart on the staff workload in a radiation oncology department.

BACKGROUND In order to improve the efficiency of patient care, we developed an electronic medical record system, named the Comprehensive Radiation Oncology Management System (C-ROMS). C-ROMS was used together with a commercial record-and-verify system, LANTIS (Siemens Medical Systems Inc., Concord, CA, USA). The impact of the C-ROMS/LANTIS system on the staff workload in the Radiation Oncology ...

متن کامل

Anomaly? Application Change? or Workload Change?

Automated tools for understanding application behavior and its changes during the application life-cycle are essential for many performance analysis and debugging tasks. Application performance issues have an immediate impact on customer experience and satisfaction. A sudden slowdown of enterprise-wide application can effect a large population of customers, lead to delayed projects and ultimate...

متن کامل

Reimbursement versus effort in medical physics practice in radiation oncology

The changes in health care reimbursement have the potential to affect the availability of quality medical physicist service in patient care. A survey was conducted by the AAPM Professional Council and the ACMP to collect cost information for special medical physics consultation, CPT4-77370 and continuing medical physics, CPT4-77336. The data collected from the survey was compared to current rei...

متن کامل

Medical physics aspects in accreditation of radiation oncology practice

Diagnosis of cancer is usually a life‑changing experience for patients and their loved ones. As they seek treatment for their disease, cancer patients need to know that they are receiving safe and appropriate care. When the cancer patient receives radiation treatment at an accredited radiation oncology facility, he can rest assured that his treatment will be done at a facility that has met the ...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 15  شماره Special Issue-12th. Iranian Congress of Medical Physics

صفحات  235- 235

تاریخ انتشار 2018-12-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023