Radiation exposure during percutaneous nephrolithotomy; Is there a risk of the patient and the operating team?
نویسندگان
چکیده مقاله:
Background: The aim of this study was to calculate the radiation amount exposed during percutaneous nephrolithototomy (PCNL) and to make the urologists and other staff sensitive about the radiation risk they were exposed to. Materials and Methods: We measured the radiation exposure during 114 cases of PCNL performed. Thermoluminescent dosimeters (TLD) were placed between the operation table and the patient at the location of kidney and gonads of patients to measure the radiation exposure of patients. TLD were placed at the head, neck, finger and the legs of the operating surgeon to measure the occupational exposure of the urologist. And also two dosimeters were placed to the inner wall of the operating room and two dosimeters were placed to the hall. Results: The mean fluoroscopy screening time was 2.18 minutes (0.15 - 6.12) and the mean operation time was 49 minutes (10-150). The mean radiation exposure for patients was 1.307 milisievert (mSv) at kidney location and 0.562 mSv at gonad location per procedure. Surgeon exposure was 0.021 and 0.003 mSv per procedure for hand and leg, respectively. Radiation amounts exposed inside the room and by the surgeon were statistically significantly lower than measured radiation results compared to patient kidney. Conclusion: According to our findings radiation exposure of the patient and the surgeon is below the annual occupational dose limit recommendations. However, for protecting from stochastic effects of radiation, fluoroscopy should be used as low as possible and lead aprons and thyroid shields must be worn to minimize the radiation exposure.
منابع مشابه
Radiological risk and radiation of the percutaneous nephrolithotomy patient.
also analyzed in both groups of patients, the sample size was not planned to be powered to detect statistical differences in this variable, as it was already in the editorial of the same issue ‘‘New Eng’’. We studied low-risk candidates for active surveillance based on PRIAS/START criteria. Over 40% had unfavorable pathological findings. More than 18% had biochemical progression (Table 1). Albe...
متن کاملPredictors of radiation exposure to providers during percutaneous nephrolithotomy
BACKGROUND Limited studies have reported on radiation risks of increased ionizing radiation exposure to medical personnel in the urologic community. Fluoroscopy is readily used in many urologic surgical procedures. The aim of this study was to determine radiation exposure to all operating room personnel during percutaneous nephrolithotomy (PNL), commonly performed for large renal or complex sto...
متن کاملmesuring the staff technology readiness, the case of a multi national chemical company operating in iran
چکیده ندارد.
15 صفحه اولthe investigation of the relationship between type a and type b personalities and quality of translation
چکیده ندارد.
A novel dosimeter for measuring the amount of radiation exposure of surgeons during percutaneous nephrolithotomy: Instadose™
INTRODUCTION The aim of this study was to demonstrate the efficacy of Instadose™, a novel dosimeter designed for radiation workers to provide a measurement of the radiation dose at any time from any computer; to determine the amount of radiation exposure during percutaneous nephrolithotomy (PNL); and to evaluate the factors that affect the amount of radiation exposed. MATERIAL AND METHODS Two...
متن کاملمنابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ذخیره در منابع من قبلا به منابع من ذحیره شده{@ msg_add @}
عنوان ژورنال
دوره 16 شماره None
صفحات 133- 138
تاریخ انتشار 2018-01
با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.
میزبانی شده توسط پلتفرم ابری doprax.com
copyright © 2015-2023