Quantitative Assessment of Conventional and Modern De-Noising on Nuclear Medicine Images

نویسندگان

  • E. Hajizade Associate Professor, Biostatistics Dept., Tarbiat Modarres University, Tehran, Iran
  • H. Ghiasi M.SC. in Medical Physics, Torfe Hospital, Tarbiat Modarres University, Tehran, Iran
  • H. Rajabi Assistant Professor, Medical Physics Dept., Tarbiat Modarres University, Tehran, Iran
  • S.R. Zakavi Associate Professor, Nuclear Medicine Dept., Imam Reza Hospital, Mashhad University of Medical Sciences, Mashhad, Iran
  • Sh. Olumi M.SC. in Medical Physics, Tarbiat Modarres University, Tehran, Iran
چکیده مقاله:

Introduction: One of the major problems in the development of nuclear medicine images is the presence of noise. The noise level in nuclear medicine images is usually reduced by the analysis of imaging data in a Fourier transform environment. The main drawback of this environment belongs to low signal to noise ratio in high frequencies because removing noise frequencies may remove data and times information as well. This problem becomes more serious when the most important signals are non-stationary. The aim of this research is to evaluate the effect of wavelet transform on nuclear medicine image. Materials and Methods: A brain phantom-like Hoffman phantom with 4 layers was used. Planar images were acquired from the phantom, with a total count of 107 (as reference image) and from each layer separately. The counts of planar images in each layer were increased from 100 to 700 kilo counts in seven steps. Different levels of white (Gaussian) noise was added to the reference images using MATLAB software. Simulation images using Simset software and NCAT phantom were also produced. Wavelet transform, Butterworth, Metz, Hanning(3*3) and Wiener filters were applied on all images. The Universal Image Quality Index (UIQI) was used to evaluate the image quality. Result: Wavelet transform can increase the value UIQI (UIQI = 0.7352). The effect of wavelet transform on the improvement of image quality is much better than Butterworth (UIQI = 0.3556) and Metz (UIQI = 0.3493) but almost the same as the effect of Wiener (UIQI = 0.7626) and Hanning (3*3) (UIQI = 0.8017). Discussion and Conclusion: Although wavelet transform is not the best method of reducing noise level, but its use can reduce the noise level like filters do. Assessment of commonly used thresholds as well as new design of a special threshold for wavelet transform in nuclear medicine images can improve the performance of this transform. 

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

quantitative assessment of conventional and modern de-noising on nuclear medicine images

introduction: one of the major problems in the development of nuclear medicine images is the presence of noise. the noise level in nuclear medicine images is usually reduced by the analysis of imaging data in a fourier transform environment. the main drawback of this environment belongs to low signal to noise ratio in high frequencies because removing noise frequencies may remove data and times...

متن کامل

Selective De-noising of Sparse-Coloured Images

Since time immemorial, noise has been a constant source of disturbance to the various entities known to mankind. Noise models of different kinds have been developed to study noise in more detailed fashion over the years. Image processing, particularly, has extensively implemented several algorithms to reduce noise in photographs and pictorial documents to alleviate the effect of noise. Images w...

متن کامل

De-noising and Recovering Images Based on Kernel PCA Theory

ABSTRACT Principal Component Analysis (PCA) is a basis transformation to diagonalize an estimate of the covariance matrix of input data and, the new coordinates in the Eigenvector basis are called principal components. Since Kernel PCA is just a PCA in feature space F , the projection of an image in input space can be reconstructed from its principal components in feature space. This enables us...

متن کامل

Wavelet Threshold De- Noising for Mammogram Images

Digital mammograms are coupled with noise which makes de-noising a challenging problem. In the literature, few wavelets like daubechies db3 and haar have been used for de-noising medical images. However, wavelet filters such as sym8, daubechies db4 and coif1 at certain level of soft and hard threshold have not been taken into account for mammogram images. Therefore, in this study five wavelet f...

متن کامل

Image De-Noising and Micro Crack Detection of Solar Cells

Solar cell is known as a sustainable and environment friendly source of energy in nature. It converts sunlight directly into electricity with zero emission and also without side-effects on the environment. But, solar cells have optical and mechanical defects which include the type of micro crack, the size of crack, and the noise from electrical or electromechanical interference during the image...

متن کامل

An Efficient Technique of Noising and De-Noising Medical Images Using Support Vector Machine

Medical imaging technology is becoming an important component of large number of applications such as diagnosis, research, and treatment. Medical images like X-Ray, CT, MRI, PET and SPECT have minute information about heart brain and nerves. These images need to be accurate and free from noise. Noise reduction plays an important role in medical imaging. Various methods of noise removal such as:...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 3  شماره 1

صفحات  35- 44

تاریخ انتشار 2006-03-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023