Preclinical evaluation of 68Ga-MAA from commercial available 99mTc-MAA kit

نویسندگان

  • Afsaneh Lahooti Department of Medical Physics and Biomedical Engineering, Faculty of Medicine, Tehran University of Medical Science, Iran.
  • Amir Rabiee Radiation Application Research School, Nuclear Science and Technology Research Institute (NSTRI), Tehran, Iran.
  • Amir Reza Jalilian Radiation Application Research School, Nuclear Science and Technology Research Institute (NSTRI), Tehran, Iran.
  • Davood Beiki Research Center for Nuclear Medicine, Shariati Hospital, Tehran University of Medical Sciences, Tehran, Iran.
  • Hassan Yousefnia Radiation Application Research School, Nuclear Science and Technology Research Institute (NSTRI), Tehran, Iran.
  • Mohammad Mazidi Radiation Application Research School, Nuclear Science and Technology Research Institute (NSTRI), Tehran, Iran.
  • Parham Geramifar Research Center for Nuclear Medicine, Shariati Hospital, Tehran University of Medical Sciences, Tehran, Iran.
  • saeed shanehsazzadeh Radiation Application Research School, Nuclear Science and Technology Research Institute (NSTRI), Tehran, Iran.
  • Seyedeh Fatemeh Mirshojaei Radiation Application Research School, Nuclear Science and Technology Research Institute (NSTRI), Tehran, Iran.
  • Stephan Maus Clinic of Nuclear Medicine, University Medical Centre Mainz, Langenbeckstrasse 1, D-55131 Mainz, Germany
چکیده مقاله:

99mTc-Macroaggregated Albumin (99mTc-MAA) has been used as a perfusion agent. This study described development of the 68Ga-MAA via commercially available kits from Pars-Isotopes Company as a 99mTc-MAA kit. 68Ge/68Ga generator was eluted with suprapure HCl (0.6 M, 6 mL) in 0.5 mL fractions. The two fractions with the highest 68GaCl3 activity were generally used for labeling purposes. After labeling, the final product was centrifuged 2 times to purify the solution. Five rats were sacrificed at each exact time interval (from 15 minutes to 2 hours post injection) and the percentage of injected dose per gram (%ID/g) of each organ was measured by direct counting from 11 harvested organs of rats. The RTLC showed that labeling yields before centrifuges were 90% and 95% for Pars-Isotopes and GE kits, respectively and after centrifuges, they became 100%. The microscopic size examination showed a shift in the particle sizes post centrifuges and the biodistribution data revealed the efficiency and benefits of centrifuges in terms of preventing the of liver and bone marrow uptakes especially for Pars-Isotopes kits. Our results showed that after centrifuges of the final product, the lung uptakes increased from 89% to more than 97% of %ID/g after 5 min post injections. The whole procedure took less than 25 min from elution to the final product. Since 99mTc-MAA remained longer than 68Ga-MAA in the lung and 68Ga-MAA showed better image qualities, using 68Ga-MAA is recommended.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Preclinical Evaluation of 68Ga-MAA from Commercial Available 99mTc-MAA Kit

99mTc-Macroaggregated Albumin (99mTc-MAA) has been used as a perfusion agent. This study described development of the 68Ga-MAA via commercially available kits from Pars-Isotopes Company as a 99mTc-MAA kit. 68Ge/68Ga generator was eluted with suprapure HCl (0.6 M, 6 mL) in 0.5 mL fractions. The two fractions with the highest 68GaCl3 activity were generally used for labeling purposes. After label...

متن کامل

Clinical Evaluation of a New 99mTc-MAA Kit for Lung Scanning

Lung scanning has been recognized as a clinically useful technique for portraying macroscopic pulmonary perfusion defects since it was first reported by Wagner in 1964 (1 ). A number of radiopharmaceuticals have been proposed to assess pulmonary perfusion. Although 1 3 1 I imposes many limitations as a radiotagging agent, the use of iodinated macroaggregated albumin (I-MAA) has received wide ac...

متن کامل

Lyophilized Kit for the Preparation of the PET Perfusion Agent [68Ga]-MAA

Rapid developments in the field of medical imaging have opened new avenues for the use of positron emitting labeled microparticles. The radioisotope used in our research was (68)Ga, which is easy to obtain from a generator and has good nuclear properties for PET imaging. Methods. Commercially available macroaggregated albumin (MAA) microparticles were suspended in sterile saline, centrifuged to...

متن کامل

Evaluation of the dose received by women worker in the lung scan centers use 99mTC-MAA by experimental and simulation

One of the most important groups that can be exposed to nuclear radiation is pregnant women and their fetus. This group of people can be technicians at nuclear centers located in the patients undergoing treatment or nuclear medicine diagnostic centers. The purpose of the paper is to determine the rate of doses received by female technicians who are indirectly in the vicinity of nuclear radiatio...

متن کامل

Absent pulmonary uptake on 99mTc MAA perfusion lung scan due to severe right-to-left shunt.

c 5 XTRAPULMONARY accumulation of Tc macroaggregated albumin (MAA) is rarely een on perfusion lung scan, and has been reported n less than 4% of a study population of nearly 380 atients.1 It occurs when the agent bypasses the ungs due to a right-to-left (R-L) cardiac or pulonary shunt, when it is shunted to the portal vein efore reaching the right atrium and ventricle of he heart, and when the ...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 16  شماره 4

صفحات  1415- 1423

تاریخ انتشار 2017-11-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023