Performance Improvement of Single-Phase Transformerless Grid-Connected PV Inverters Regarding Common-Mode Voltage (CMV) and LVRT

نویسندگان

  • F. Mohammadi Faculty of Electrical and Computer Engineering, Urmia University, Urmia, Iran
چکیده مقاله:

The single-phase transformerless grid-connected photovoltaic (PV) systems, mainly the low-power single-phase systems, require high efficiency, small size, lightweight, and low-cost grid-connected inverters. However, problems such as leakage current, the DC current injection and safety issues are incorporated with transformerless grid-connected PV inverters. Besides, the new standards such as Low-Voltage Ride-Through (LVRT) capability and staying connected to the grid during the fault occurrence should be considered for the next generation of transformerless PV inverters. In this paper, a study is going underway on the LVRT capability and the Common-Mode Voltage (CMV) in a number of most common transformerless grid-connected PV inverters. In fact, by a comprehensive study on all possible switching combinations and the current paths during the freewheeling period of the selected inverters, the proposed control strategy for performance improvement of the PV inverters under the normal and the LVRT conditions is presented. As a matter of fact, a reconfigurable PWM method is proposed, which makes it possible to switch between two PWM methods and hence provide improved performance of the inverters in the LVRT condition. Finally, the results of simulations in the normal and the LVRT operations to verify the theoretical concepts are indicated.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design of A Single-Phase Transformerless Grid-Connected PV Inverter ‎Considering Reduced Leakage Current and LVRT Grid Codes

A new single-phase transformerless grid-connected PV inverter is presented in this paper. Investigations in transformerless grid-connected PV inverters indicate the existence of the leakage current is directly related to the variable common-mode voltage (CMV), which is presented in detail. On the other hand, in recent years it has become mandatory for the transformerless grid-connected PV inver...

متن کامل

Review on Single-phase PV Inverters for Grid-connected Applications

In this paper, a review of PV inverters is reported based on converter characteristics as the number of energy processing stages, the presence of a transformer (high-frequency or 50Hz transformer), and the adopted configuration of the PV field. In particular, the considered solutions have been evaluated depending on efficiency, input current ripple and life-time of the capacitors coupling with ...

متن کامل

Pll for Single Phase Grid Connected Inverters

In grid connected applications the synchronization of output signals of the converters to be connected with grid parameters frequency and phase is of great importance. Different methods based on Fourier transforms, zero-crossing detection, Kalman filters, phase-locked loops (PLL) and others are used for this synchronization. This paper presents a new PLL for synchronization of the output curren...

متن کامل

Methodology for the optimal design of transformerless grid-connected PV inverters

The transformerless PV inverters are the major functional units of modern grid-connected PV energy production systems. In this paper, a new optimization technique is presented for the calculation of the optimal types and values of the components comprising a transformerless PV inverter, such that the PV inverter Levelized Cost Of the generated Electricity (LCOE) is minimized. The proposed metho...

متن کامل

Evaluation of Single Phase Transformerless Photovoltaic Inverters

Transormerless inverters are attractive solution for the grid connected photovoltaic (PV) systems. Unfortunately, it has issues on galvanic isolation between PV systems to the grid. When the galvanic isolation disappears from the PV inverter, leakage currents will flow in a resonant circuit formed by the ground capacitance, the converter, the ac filter and the grid. In order to avoid the leakag...

متن کامل

Grid connected Converters for Photovoltaic, State of the Art, Ideas for Improvement of Transformerless Inverters

The paper presents a short overview of the state of the art for grid tied PV inverters at low and medium power level (1..100 kW), mainly intended for rooftop applications. The inverters are categorized according to the configuration of the PV system, the configuration of the conversion stages within the inverter and whether they use transformers or not [1], [3]. After the introduction of the st...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 7  شماره 1

صفحات  1- 15

تاریخ انتشار 2019-05-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023